Datasheet

CP10.361
CP-Series
36V, 6.7A, 240W, SINGLE PHASE INPUT
4. DC-INPUT
DC input Nom. DC 110-150V ±20%
DC input range Min. 88-180Vdc Continuous operation
DC input current Typ. 2.35A At 110Vdc
Allowed Voltage L/N to Earth Max. 375Vdc Continuous, according to IEC 62477-1
Turn-on voltage Typ. 80Vdc Steady state value
Shut-down voltage Typ. 70Vdc Steady state value
Typ. 55Vdc Dynamic value for maximal 250ms
Fig. 4-1 Wiring for DC Input
Instructions for DC use:
+
-
Load
L
PE
+
-
Power Supply
AC
DC
Battery
N
a) Use a battery or a similar DC source. A supply from the
intermediate DC-bus of a frequency converter is not
recommended and can cause a malfunction or damage
the unit.
b) Connect +pole to L and –pole to N.
c) Connect the PE terminal to an earth wire or to the
machine ground.
Aug. 2017 / Rev. 1.1 DS-CP10.361-EN
All parameters are specified at 36V, 6.7A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
5/29