Data Sheet
UZK12.071, UZO12.07
U-Series
BATTERY MODULE 12V, 7AH
10. INSTRUCTIONS FOR REPLACING BATTERIES
Batteries need to be replaced periodically. The time interval depends on the ambient temperature in which the battery
is used and on the number and depth of discharge cycles. In a typical application it is recommended to replace the
batteries at least every 2 years.
Disconnect battery fuse before replacing the battery.
Regarding disposal of used batteries see chapter 6.
Fig. 10-1 Replacing the battery
To replace battery:
1) Loosen screws (1) with only one turn.
(Use a flat-blade or Torx T20 screwdriver)
2) Slide the mounting bracket (2) sideways.
3) Tilt the mounting bracket to the front and
take it off.
4) Unplug the battery terminals.
5) Remove the battery.
6) To insert the new battery use same
procedure vice versa.
Aug. 2017 / Rev. 2.2 DS-UZK12.071
All parameters are typical values specified at, 25°C ambient temperature unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
5/11