User Instructions

INSTALLATION INSTRUCTIONS
ENGLISH
Code: AWO 622
Name: Surface mounted DIN 2/100 enclosure
IM622
Edition: 5 from 20.10.2020
Supercedes edition: 4 from 01.03.2018
1. Application:
Thanks to its design, the AWO622 enclosure can be used both as a stand-alone component used for mounting of all DIN rail
mounted devices and an element integrating electrical installations, e.g. CCTV, Access Control Systems (ACS), Intrusion
Detection Systems (IDS), etc. The enclosure is designed for mounting of (depending on the configuration):
1. Electric fuses of the „S” type
2. Transformers of the following series: TRP, TRZ
3. Power supplies of the following series:
PS-15xxx, PS-40xxx, PS-60xxx, PS-100xxx, PS-150xxx, PS-200xxx
DINxxx
4. Built-in buffer power supplies of the following series:
PSB-25xxx, PSB-35xxx, PSB-50xxx, PSB-75xxx, PSB-100xxx, PSB-155xxx, PSB-300xxx
PSBOC25xxx, PSBOC35xxx, PSBOC50xxx, PSBOC75xxx, PSBOC100xxx, PSBOC155xxx, PSBOC300xxx
5. MEAN WELL power supplies for DIN rail of the following series:
MDR, DR, HDR, EDR, NDR, SDR
DRP, DRH, WDR, TDR, DRC
DR-UPS40 (buffer module)
DRDN20, DRDN40, DR-RDN20 (redundant modules)
6. MEAN WELL built-in power supplies of the following series:
RS, LRS, RD, RSP, HRP, QP, AD, ADD, SCP
2. Product description
Enclosure on the rear wall has holes for mounting 2 DIN rails, each 320mm long.
Rails are mounted directly to enclosure or on plastic brackets that allow separate rail from wall by 20mm. Additionally, it
has holes for mounting in the rear wall TRP series transformers, buffer power supplies up to 155W. PSB power supplies
with a power above 155W can be mounted on a DIN rail using PSDIN2 adapter. Equipped with a tamper detecting the
opening enclosure. Enclosure is screwed from the front, as standard option. Front of enclosure has an embossing for a
lock, which allows to assembly a lock with the same code MR027 or with a different code MR008. Plastic 14mm spacers
are added to enclosure, which allow moved it from the wall, which allows entry cables to devices mounted in enclosure.
3. Mounting:
The enclosure should be mounted by a qualified installer, holding relevant (applicable and required for a given country)
permits and licenses for low-voltage installations.
The enclosure (+PCB) shall be mounted in confined spaces with normal air humidity (RH=90% max. without
condensation) and the temperature from -10°C to +40°C.
4. Technical parameters
TECHNICAL PARAMETERS
Battery space
2 x 17Ah /12V
Tamper protection
1x enclosure opening
TAMPER output load- max
500mA@50 V DC
Enclosure
IP 20
Operation temperature
-10ºC÷40ºC
Relative humidity RH max
90 [%]
External dimensions of the enclosure
W=375, H =410, D+D
1
=100+14 [-/+2mm]
External dimensions of the front panel
W
1
=380, H
1
=415 [+/- 2mm]
The number of DIN rails/ length / the number of „S” fields
D
2
= 4 or 20 [+/- 1mm]
2/320mm/18