Data Sheet

Table Of Contents
DESCRIPTION
against reverse input voltage polarity
The DCDC converter is used for powering devices that require stabilized voltage of 12 V DC. The maximum
current load is 1,5 A* (Pmax= 18 W). This module does not have galvanic insulation between the input and output
(IN-AUX), and operates on a common ground potential . The unit is protected against short circuit, overload and
.
DCDC15H
12V/ 62MM DC/DC converter1,5A/
CODE:
TYPE:
EN/VI
ACCESSORIES
ACCESSORIES :
[1] adapter CABLE - PLUG DC 5,5/2,1 - code ML109
Chart 1.
Relation between output current
and ambient temperature (instantaneous load).
Fig.1.
Mechanical view and dimensions of the convetrer.
wyjście TAMPER : przewody 30cm
Tel. +48-14-610-19-40, fax: +48-14- 610-19-50, www.pulsar.pl, e-mail: sales@pulsar.pl
DC/DC converter
DC/DC conwerter 12VDC, IP67
Pulsar
®
Features:
· Power output 1,5 A/12 V DC*
· DC power supply range 18÷40 V DC
· high efficiency 86 %
· IP 67 enclosure
· protections:
· against short circuit protection
· overload protection OLP
· against reverse input voltage polarity
· warranty – 2 year from the production date
SPECIFICATIONS.
For the converterss are available
accessories - cable adapter.
For details –visit .www.pulsar.pl
Supply voltage 18 ÷ 40 V DC
Supply power 18 W max.
Efficiency 86 %
Output voltage 12 V DC
Current consumption by PSU systems 5 mA max.
Output current t
AMB
<30 °C 1,5 A - refer to graph 1.
Output current t
AMB
=40 °C 1 A - refer to graph 1.
Ripple voltage 100 mV p-p max.
Protection against short circuits (SCP) and
overloads(OLP)
200 % ÷ 250 % of module power – output power limit,
automatic return after elimination of short circuit
IP protection class IP67
Operation conditions temperature -10
o
C÷40
o
C
relative humidity 20 %...90 %
Dimensions (LxWxH) 58 x 58 x 28 [mm]
Net/gross weight 0,16 kg / 0,19 kg
Protection class PN-EN 60950-1:2007 II (second)
Length of DC input cable 0,3 m
Length of DC output cable 0,5 m + plug DC5,5/2,1 female
Storage temperature -20 ºC...+60 ºC
Declarations, warranty CE, 2 year from the production date
IN / PWY
100%
70%
30°C
40°C
ta
0°C
* In order to extend the life of the converter, the load current of 1 A is recommended.
* Refer to chart 1