4. Ethernet interface configuration.
4.1 Introductory information.
Ethernet interface parameters can be configured to adapt to the actual operation. Configuration is done
using the „PowerConfig” program.
The „PowerConfig” program is available on:
http://www.pulsar.pl/pliki/PowerConfig.exe
A newly purchased Ethernet interface is supplied in basic configuration (factory settings) which is not
adapted for correct operation of the system.
Since the communication with the interface uses a network cable, there is a need for proper configuration of the
router in order to establish a connection with the interface. The most convenient solution is to own a separate
router or to restore the factory settings of already owned router (if possible).
The information included in the following subsections show „step by step” how to configure the Ethernet
interface.
4.2 STEP 1 - Restoring the factory settings.
Router:
In order to restore the factory settings of the router, check the device’s manual and perform the appropriate
actions following the manufacturer's instructions. In most cases it is enough to find the reset button on the rear side
of the enclosure and hold it for approximately 5 seconds. After releasing the reset button, wait about 1 minute for
the correct initialization of the router.
Ethernet interface INTE:
In order to restore the factory settings of the interface, turn off the power, put the "RST" jumper on and turn
on the power. The factory settings will be restored after 3 seconds. The jumper must be removed before performing
further operations.