CAL.
MODE CHANGE C 1-AL P M 24 A A With each press, the mode in the digital display changes in the following order: ➡ STOPWATCH ➡ TIMER ➡ REGULAR ALARM ➡ TIME/ CALENDAR 2 C Press in TIME/CALENDAR mode to show SINGLE-TIME ALARM mode.
SCREW DOWN CROWN [for models with screw down crown] Unlocking the crown 1 Turn Crown counterclockwise until you no longer feel the threads turning. 2 Crown can be pulled out. Locking the crown 1 Push Crown back in to normal position. 2 Turn Crown clockwise while pressing it lightly until tight.
TIME/CALENDAR MODE ● Before setting the analogue time, be sure to set the digital time. DIGITAL TIME/CALENDAR SETTING A Date ▲ Day C A Press to show TIME/ CALENDAR mode. Press for 2 to 3 seconds. ▲ 1-AL P M 24 ▲ C ▲ D 4 D Set the flashing digits. ▲ A Select the digits to be adjusted.✽ A Return to TIME/CALENDAR mode.
✽ Selection of the digits 12-/24-hour indication ➾ ➾ Seconds ➾ Minutes ➾ Hour ➾ Year ➾ Month ➾ Date ANALOGUE TIME SETTING Second hand CROWN Hour hand Minute hand ➠ 2 Turn to set the hour and minute hands. ➠ P M 24 1 Pull out when the second hand is at the 12 o’clock position. 3 Push back in to normal position when the second digits count “00” in the digital time display.
CHANGEOVER OF DISPLAYS D With each press in TIME/CALENDAR mode, the display changes in the following order: ➡ Calendar display ➡ Blank display ➡ Time/calendar display DEMONSTRATION FUNCTION ● The watch shows the modes and displays in order. D Press for 2 to 3 seconds in TIME/CALENDAR mode to start the demonstration.
STOPWATCH MODE ● The stopwatch measures up to 24 hours in 1/100 second increments for the first hour and in 1 second increments thereafter. A Press to show STOPWATCH mode.
TIMER MODE ● The timer can be set up to 9 hours and 59 minutes in minute increments. ● The remaining time is displayed in seconds. A Press to show TIMER mode. TIMER SETTING A C ▲ ▲ C ▲ 1-AL P M 24 Press for 2 to 3 seconds. D Select the digits to be adjusted (hour/minutes). Set the flashing digits. ▲ 8 A D A Return to TIMER mode.
TIMER OPERATION 1-AL C Start / Stop / Restart D Reset P M 24 * When the set time is up, a warning sound beeps for 10 seconds. To stop it manually, press any of the buttons.
REGULAR ALARM MODE ● The regular alarm can be set to ring on a 24-hour basis. A Press to show REGULAR ALARM mode. REGULAR ALARM SETTING A C ▲ ▲ C ▲ 1-AL P M 24 Press for 2 to 3 seconds. D Select the digits to be adjusted (hour/minutes). Set the flashing digits. ▲ A 10 D A Return to REGULAR ALARM mode.
* The regular alarm mark is automatically displayed and the regular alarm is engaged. ENGAGEMENT/DISENGAGEMENT OF REGULAR ALARM AND HOURLY TIME SIGNAL C 1-AL C P M 24 With each press, the engagement/ disengagement of the regular alarm and hourly time signal are made as follows: ▲ Regular alarm engaged ▲ Hourly time signal engaged ▲ Hourly time signal mark Both engaged ▲ Regular alarm mark Neither engaged * At the designated time, the regular alarm rings for 20 seconds.
SINGLE-TIME ALARM MODE ● The single-time alarm can be set to ring only once at the designated time. As it rings, it is automatically disengaged. ● The single-time alarm can be set in minute increments starting from the current time. SINGLE-TIME ALARM SETTING A Designated alarm time Press to show TIME/ CALENDAR mode. ▲ Single-time alarm mark C C Press to show SINGLE-TIME ALARM mode. ▲ 1-AL C P M 24 or D Select the desired alarm time. ▲ A 12 A D Current time Return to TIME/CALENDAR mode.
* At the designated time, the single-time alarm rings for 20 seconds. To stop it manually, press any of the buttons. ● To cancel the single-time alarm you have set, press buttons C and D at the same time in the SINGLE-TIME ALARM mode, or press button C or D to set the alarm time to the current time. ILLUMINATING LIGHT Electroluminescent panel) B B 1-AL P M 24 Press in any mode. * The digital display is evenly illuminated for 3 seconds.
ViViDiGi ● is a new type of liquid crystal panel that makes possible various colors and high contrast. ● Excellent light reflection and transmission make the display bright and clear. ● Various color options are available. ● Either the whole panel or the displayed data only can be illuminated. * Features vary in different models.
● Setting the seconds: • With the second digits flashing, press button D in accordance with a time signal. The second digits are reset to “00”. • When the seconds count any number from “30” to “59” and button D is pressed, one minute is added and the seconds are reset to “00”. ● The flashing digits except the seconds and 12-/24-hour indication move quickly if button D is kept pressed. ● When setting the hour digits in the 12-hour indication, check that AM/PM is properly set. Only the “PM” mark is displayed.
TIMER MODE [TIMER SETTING] ● Before setting the desired time for the timer, reset the digits to “0:00'oo” by pressing button D. ● The flashing digits move quickly if button D is kept pressed. ● If the watch is left untouched with the digits flashing, it will automatically return to the TIMER mode in 1 to 2 minutes. [TIMER OPERATION] ● Restart and stop of the timer can be repeated by pressing button C.
button C to engage/disengage the regular alarm/hourly time signal as desired. SINGLE-TIME ALARM MODE [SINGLE-TIME ALARM SETTING] ● When button C or D is pressed to set the single-time alarm, the single-time alarm mark “1-AL” is displayed and the single-time alarm is automatically engaged. ● With each press of button C or D, one minute is advanced or moved back, respectively.
BATTERY CHANGE 2 Years Battery life : Approx. 2 years Battery : SEIKO SR626SW, 1 piece (for analogue display) SEIKO SR41W, 1 piece (for digital display) ● The battery life may be less than 2 years if the alarm is used for more than 10 seconds a day and/or the illuminating light more than once (for 3 seconds) a day. ● Even if either of the two batteries has run down, replace both of them with new ones.
Press and hold buttons A, B, C and D at the same time for 2 to 3 seconds. When the buttons are released, “12:00'00" a.m., Jan. 1st, 2000, SAT” will be displayed. * Before using the watch, set the time/calendar and then, the alarm. WARNING ● Do not remove the battery from the watch. ● If it is necessary to take out the battery, keep it out of the reach of children. If a child swallows it, consult a doctor immediately. ● Never short-circuit, tamper with or heat the battery, and never expose it to fire.
TO PRESERVE THE QUALITY OF YOUR WATCH WATER RESISTANCE ● Non-water resistant • If the watch becomes wet, have it checked by an AUTHORIZED PULSAR DEALER or SERVICE CENTER. ● Water resistant 5/10/15/20 bar 5 bar WR 10/15/20 bar WR 20 • Before using in water, be sure the crown is pushed in completely. • Do not operate the crown and buttons when the watch is wet or in water. If used in sea water, rinse the watch in fresh water and dry it completely.
* Pressure in bar is a test pressure and should not be considered as corresponding to actual diving depth since swimming movement tends to increase the pressure at a given depth. Care should also be taken on diving into water. ** We recommend that you wear a PULSAR Diver’s Watch for scuba diving.
SHOCKS & VIBRATION PERIODIC CHECK Light activities will not It is recommended that the affect your watch, but be watch be checked once 2-3 careful not to drop your every 2 to 3 years. Have Years watch or hit it against hard your watch checked by an surfaces, as this may AUTHORIZED PULSAR cause damage. DEALER or SERVICE CENTER to ensure that the case, crown, buttons, gasket and crystal seal remain intact.
STATIC ELECTRICITY The IC (Integrated Circuit) used in your watch will be affected by static electricity which may disturb the display. Keep the watch away from close contact with objects such as TV screens which emit strong static electricity. LIQUID CRYSTAL PANEL The normal life expectancy for the liquid crystal panel of the watch is approximately 5 years. 5 Years After that it may decrease in contrast, becoming difficult to read.