Operating instructions

www.pulsar.pl POE084824B GREEN POWER CCTV PoE
8
- battery output (0V): BAT- cable / black
10. Check the optical indication of the PSU status: green LED light on the PoE module.
11. Close the cover after installing and checking the operation of the power supply.
3. Power supply operation indication.
3.1. Optical indication.
The PSU has 11 LED lights at the front panel:
RED LED:
on The PSU supplied with 230V AC voltage
off no 230V AC mains supply
RED LED:
on DC voltage at the output of the switch mode PSU
off no DC voltage at the output of the switch mode PSU
RED LED:
on fuse failure at one of the AUX1…AUX8 outputs
off no failure
GREEN LED:
on DC voltage at the AUX1…AUX8 output
off no DC voltage at the AUX1…AUX8 output
Additionally, the PSU is fitted with LED lights inside the enclosure see Fig. 2 and 3:
- L
AC
red LED (Fig. 2, component 1) is permanently illuminated during normal operation (AC power ON).
No AC power is indicated by turning off the L
AC
LED.
- L
IN
green LED (Fig. 2, component 1) indicates DC voltage at the PoE module input. During normal operation (DC
supply) the LED is permanently illuminated. No DC no DC voltage at the module input is indicated by turning off the L
IN
LED.
- L
FPS
red LED (Fig. 2, component 10) is not illuminated during normal operation (no failure). In case of activation of the
short circuit / overload protection at any output, the LED is permanently illuminated.
- L1 ÷ L8 green LEDs (Fig. 2, component 5) indicate voltage at the individual outputs of the module (L1 for AUX 1 etc.).
Activation of the short circuit / overload protection of a given circuit is indicated by turning off one of the Lx LEDs.
3.2. Technical outputs.
The PSU has the following indication outputs:
FPS technical output of the PSU status:
- OC type output indicating failure (short-circuit, overload). During normal operation, shorted to ground L state
(0V). In case of power loss, the FPS technical output is switched into hi-Z state (high impedance) at least at one of
the AUX outputs.
Fig. 6. Electrical diagram of the OC output.
- relay output. In case of failure, relay contacts are switched automatically.
Fig. 7. Electrical diagram of the relay output.