User Instructions

www.pulsar.pl PSUPS10A12CR
6
Battery charging current
1A
Approximate backup time
1h 30min
Short-circuit protection SCP - circuit of
cameras
STRIP LB8: 8x F 1 A glass fuse,
Output filter 1xF 5 A
Overload protection OLP
105% ÷ 150% of the PSU power, automatic recovery
Short-circuit protection SCP - circuit of
recorder
F5 A melting fuse in the filter
Battery circuit protection SCP and reverse
polarity connection
glass fuse 15 A
Surge protection
varistors
Over voltage protection OVP
>16 V (automatic recovery)
Deep discharge protection UVP
U<9,5 V (± 5%) disconnection of battery terminal
Sabotage protection:
- TAMPER output indicating enclosure
opening
- micro-switches, NC contacts (enclosure closed),
0,5 A@50 V DC (max.)
Optical indication: front panel of the PSU
- AC OK.; LED indicating the AC power
status
- DC OK.; LED indicating the DC supply at
the PSU output
- red, normal status on, failure: off
- green, normal status on, failure: off
Table 5. Mechanical specifications.
Dimensions
W=420, H=535, D+D
1
=193+14 [+/- 2mm]
W
1
=425, H
1
=540 [+/- 2mm]
The dimensions of the
recorder compartment
W
2
=380, H
2
=320, D
2
=65 [+/- 2mm]
The dimensions of the
battery compartment
180 x 170 x 80 mm (WxHxD) max
Fixing
See Fig. 3
Net/gross weight
8,33 / 9,06 kg
Enclosure
Steel plate DC01 1,0mm, colour RAL 9003
Closing
Cheese head screw x 2 (at the front)
The possibility of installing two locks with different codes.
Connectors
Mains supply: Φ0,63-2,50 (AWG 22-10)
Outputs for cameras: Φ0,63-2,50 (AWG 22-10)
Recorder outputs: power cord 55cm, terminated with the DC 5,5/2,1 plug
Battery outputs: Ф6/2,5mm
2
TAMPER output: wires
Notes
The enclosure does not adjoin the assembly surface so that cables can be led.
Forced cooling - built-in fan.
Table 6. Operation safety.
Protection class EN 60950 -1:2007
I (first)
Protection grade EN 60529: 2002 (U)
IP20
Electrical strength of insulation:
- between input (network) circuit and output circuits of the PSU
- between input circuit and protection circuit
- between output circuit and protection circuit
3000 V AC min.
1500 V AC min.
500 V AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100MΩ, 500 V DC