User Instructions
www.pulsar.pl PSUPS10A12CR
8
RED LED:
on – The PSU supplied with 230 V voltage
off – no 230 V mains supply
GREEN LED:
on – DC voltage at the AUX output
off - no DC voltage at the AUX output
4. Mount the recorder in a designated area of the housing.
5. Connect the power supply of the DVR (by default, the device is equipped with a cable terminated with the DC 2.1
/ 5.5 plug).
6. Connect the camera cables to the AUX1…AUX8 connectors of the LB8 modules.
7. Connect the batteries.
8. Connect the power (~230 V).
9. Check the PSU output voltage:
- the PSU voltage without load should amount to U=13,8 V DC.
10. Check the PSU operation indicator: green LED (on the power supply module).
11. After installing and checking proper working, the enclosure can be closed.
3. Operating status indication.
The PSU is equipped with two diodes on the front panel:
4. Operation and use.
4.1 Overload or short circuit of the PSU output (SCP activation).
In case of overload, the output voltage is automatically shut off, and so is the LED indicator. The restoration of
the voltage takes place immediately once the failure (overload) is over.
4.2 Overload or short circuit of the recorder’s module or CCTV camera module
The modules of the recorder and CCTV cameras are protected against a short circuit by fuses (fuse-elements). In
case of fuse replacement, use a replacement of the same parameters, in conformity with specific norms and power
balance.
4.3 Battery-assisted operation.
The power supply is equipped with deep discharge battery protection (UVP). If the voltage at the battery terminals
drops below 9,5 V during battery-assisted operation, the batteries will be disconnected.
4.4 Maintenance.
Any and all maintenance operations may be performed following the disconnection of the PSU from the power
supply network. The PSU does not require performing any specific maintenance measures. However, in case of dust,
clean the interior with compressed air. In case of fuse replacement, use a replacement of the same parameters.
WEEE MARK
According to the EU WEE Directive – It is required not to dispose of electric or electronic waste as
unsorted municipal waste and to collect such WEEE separatel.
CAUTION!
The power supply unit is adapted for cooperation with the sealed lead-acid batteries (SLA). After the operation period
they must not be thrown but recycled according to the applicable law.
Pulsar sp. j.
Siedlec 150, 32-744 Łapczyca, Polska
Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50
e-mail: biuro@pulsar.pl, sales@pulsar.pl
http:// www.pulsar.pl, www.zasilacze.pl