RSFUPS108 v.1.2 RSFUPS108 10-ports switch with buffer power supply for 8 IP cameras, RACK mounted EN Edition: 4 from 14.02.2019 Supercedes the edition: 3 from 09.03.
www.pulsar.pl RACK POWER RSFUPS108 Features: DC 52 V uninterruptible power supply of 8 IP cameras Switch 10 ports 8 PoE 10/100 Mb/s ports, (1÷8 ports) (data and power supply) 2 ports 10/100/1000 Mb/s (ports G1/TP, G2/TP) (UpLink) 2 ports 10/100/1000 Mb/s SFP (G1/SFP, G2/SFP ports) 30 W for each PoE port, supports devices complaint with the IEEE802.
www.pulsar.pl RSFUPS108 RACK POWER 1. Technical description. 1.1. General description. The RSFUPS108 is a complete solution for power supply and battery backup of 8 IP cameras (52 V DC power supply) in RACK 19" standard.
www.pulsar.pl RSFUPS108 BAT – battery output ALARM – technical output of collective failure – relay BUZZER, micro switch, turning ON / OFF of acoustic indication switch in the top position, indication ON switch in the down position, indication OFF PoE port 1÷8 for cameras IP connection (data + power supply) 2 x UPLINK ports (G1/TP, G2/TP) 2 x UPLINK ports (G1/SFP, G2/SFP) 230 V AC INPUT, power socket 230 V, power cable 1,5 m included FMAINS, fuse in the supply circuit 230 V, T 3,15 A/250 V Fig. 2.
www.pulsar.pl RACK POWER RSFUPS108 Fig.5. The view of the switch. Table 2. (See Fig. 5). Element no. [Fig. 2] Description LINK - yellow LED - indicating the LAN connection status PoE - green LED indicating voltage at the PoE port PWR - green LED indicating the supply voltage of the Switch PoE port 1÷8 for cameras IP connection (data + power supply) 2 x UPLINK ports (G1/TP, G2/TP) 2 x UPLINK ports (G1/SFP, G2/SFP) 1.4. Specifications. - parameters of the switch (tab.3) - electrical parameters (tab.
www.pulsar.pl RACK POWER RSFUPS108 Excessive discharge protection UVP Optical indication of operation: Acoustic operation indication: The ALARM technical output of collective failure The FMAINS fuse in the 230 V power supply circuit U<19 V (+/-5 %) – disconnect of connection battery LED: AC, DC, TEMP, LoB, ALARM, LINK, PoE Piezoelectric indicator ~75 dB/0,3 m Relay type: 1 A@ 30 V DC/50 V AC T 3,15 A Mechanical parameters (tab. 5).
www.pulsar.pl RSFUPS108 RACK POWER 2. Installation. 2.1. Requirements. The PSU RACK shall be mounted by a qualified installer with appropriate permissions and qualifications for 230 V installations and low-voltage installations (required and necessary for a given country). The device shall be mounted in confined spaces, according to the environment class II, with normal air humidity (RH=90 % max. without condensation) and the temperature from -10 °C do +40 °C.
www.pulsar.pl RSFUPS108 RACK POWER 3. Indication of the device operation. 3.1. LED indication of operating status.
www.pulsar.pl RSFUPS108 RACK POWER 3.3. Technical output. The power supply is fitted with the ALARM output of collective failure (relay type). A collective failure can be triggered by the following events: - 230 V mains power failure - Failure of the switch mode power supply - Too high temperature of the switch mode power supply (>70 °C) - Low battery voltage (<23 V) Fig. 5. Electrical diagram of the ALARM collective output of failure. CAUTION! In Fig.
www.pulsar.pl RSFUPS108 RACK POWER WEEE LABEL Waste electrical and electronic equipment must not be disposed of with normal household waste. According to the European Union WEEE Directive, waste electrical and electronic equipment should be disposed of separately from normal household waste. The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled according to the applicable law. Pulsar sp. j.