User Instructions

www.pulsar.pl RUPS1612RP RACK POWER CCTV
5
Ripple
120 mV p-p max.
Battery charge current
(batteries 1x17Ah/ 1x28Ah/ 1x40Ah/ 1x65Ah)
2A max. (+/-5%)
Approximate backup time
4h 30min
Short-circuit protection SCP
cameras: 16 x PTC 1A, polymer fuse
recorder: 1 x F 4A, glass fuse
Overload protection OLP
Current consumption by PSU systems
105% ÷ 150% of the PSU power, automatic return
0,33A
Overvoltage protection OVP
>16V (activation requires disconnecting the load or supply for
about 20s.)
Battery circuit protection SCP and reverse
polarity connection
glass fuse 30A
Surge protection
varistors
Excessive discharge protection UVP
U<9,5V (+/-5%) disconnect of connection battery
Optical indication of operation:
LED: AC, DC, TEMP, LoB, ALARM, AUX1÷AUX16
Acoustic operation indication:
Piezoelectric indicator ~75dB/0,3m
The ALARM technical output of collective failure
Relay type: 1A@ 30V DC / 50V AC
The F
MAINS
fuse in the 230V power supply circuit
T 6,3A
F
DVR
fuse in the recorder power supply circuits
F 4A
Mechanical parameters (tab. 3).
Mounting dimensions
W=19”, H=2U, D=267
Dimensions
W=482, W
1
=442, H=88, D=267, D
1
=32, D
2
=10 [+/- 2mm]
Fixation
four-point butt mounting to RACK profiles the set include 4 M6 screws + cage nuts
Net weight
6,2kg / 6,6kg
Enclosure
Steel plate RAL 9005, black
Connectors
230V AC input: the IEC C14 socket with a fuse, power cable 2m
(included)
Outputs: ALARM, AUX1÷AUX16: Φ0,5-2,1 (AWG 24-12) 0,5-1,5mm
2
Output DVR: Φ0,5-2,1 (AWG 24-12) 0,5-1,5mm
2
, power cable 2m (included)
Battery output BAT: 6,3F-2,5
Notes
Forced cooling (fan).
Operation safety (tab.4).
Protection class PN-EN 60950-1:2007
I (first)
Protection grade PN-EN 60529: 2002 (U)
IP20
Electrical strength of insulation:
- between input and output circuits of the PSU (I/P-O/P)
- between input circuit and PE protection circuit (I/P-FG)
- between output circuit and PE protection circuit (O/P-FG)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100 MΩ, 500V/DC
Operating parameters (tab.5).
Environmental class
II
Operating temperature
-10ºC...+45ºC
Storage temperature
-20ºC...+60ºC
Relative humidity
20%...90%, without condensation
Vibrations during operation
unacceptable
Impulse waves during operation
unacceptable
Direct insulation
unacceptable
Vibrations and impulse waves during transport
According to PN-83/T-42106