CAL. V011, V041 ALARM CHRONOGRAPH ● Analogue time and digital time/calendar ● Regular alarm ● Stopwatch ● Illuminating light (for Cal.
DISPLAY AND CROWN/BUTTONS B Pulsar QUARTZ CROWN A ● With each press of button A, the digital display changes as follows: TIME/CALENDAR SETTING display ALARM display ➮ STOPWATCH display TIME display ➮ 2 ➮ ➮ ➮ CALENDAR display
SCREW DOWN CROWN [for models with screw down crown] Unlocking the crown 1 Turn Crown counterclockwise until you no longer feel the threads turning. 2 Crown can be pulled out. Locking the crown 1 Push Crown back in to normal position. 2 Turn Crown clockwise while pressing it lightly until tight.
DIGITAL TIME/CALENDAR SETTING Press to show TIME/CALENDAR SETTING display. A ▲ B ▲ Pulsar B Select the digits to be adjusted.✽ ▲ A QUARTZ Set the flashing digits. ▲ A Press to show TIME/CALENDAR SETTING display. B ▲ A Press to show CALENDAR display.
ANALOGUE TIME SETTING ● Be sure to set the digital time first before setting the analogue time. CROWN Pulsar 1 Pull out when Second hand is at the 12 o’clock position. 1 2 QUARTZ 3 2 Turn to set Hour and Minute hands. 3 Push back when the seconds in the digital time display count “00”. ILLUMINATING LIGHT (for Cal. V011) ● The illuminating light is activated by continuously pressing button B in the TIME or CALENDAR display.
ALARM ALARM TIME SETTING A Press to show ALARM display. ▲ B B Pulsar ▲ ▲ QUARTZ B Press to activate the alarm setting function. Select the digits to be adjusted.✽ ▲ A A Set the flashing digits. ▲ ALARM display mark B Press to show ALARM display.
ENGAGEMENT/DISENGAGEMENT OF ALARM AND HOURLY TIME SIGNAL Press to show CALENDAR or TIME display. A ▲ B Pulsar A and B With each simultaneous press, alarm and hourly time signal are engaged and disengaged in order: QUARTZ Both engaged ➮ A Alarm disengaged Hourly time signal engaged ➮ Hourly time signal mark Alarm mark Alarm engaged Hourly time signal disengaged ➮ * The alarm rings at the designated time for 20 seconds. To stop it manually, press button A or B.
STOPWATCH ● The stopwatch measures up to 60 minutes in 1/100 second increments. A Press to show STOPWATCH display. ▲ B Pulsar B Start. ▲ QUARTZ Stop. ▲ A B Minutes 8 B 1/100 seconds Seconds Reset.
NOTES ON OPERATING THE WATCH DIGITAL TIME/CALENDAR SETTING ● When setting the flashing digits, they are advanced quickly by keeping button A pressed, except the seconds and 12-/24-hour indication. ● Seconds digits setting: The seconds are reset to “00” by pressing button A. * When the seconds count any number from “30” to “59” and button A is pressed, one minute is added and the seconds are reset to “00”. ● The changeover between 12- and 24-hour indications is made alternately with each press of button A.
ANALOGUE TIME SETTING ● When setting the minute hand, first advance it 4 to 5 minute ahead of the desired time and then turn it back to the exact minute. ● When the crown is pushed in, the minute hand may move slightly. However, this is not a malfunction. ALARM ● By pressing button B with the alarm setting function activated, the alarm mark is displayed and the alarm is automatically engaged. ● When setting the alarm in the 12-hour indication, check that AM/PM is properly set. Only “P” (PM) is displayed.
BATTERY CHANGE 2 Years Battery life : Approx. 2 years Battery : SEIKO SR726W ● If the alarm is used for more than 20 seconds a day and/or the hourly time signal more than 24 times a day, the battery life may be less than the specified period. ● As the battery is inserted at the factory to check the function and performance of the watch, its actual life once in your possession may be less than the specified period.
WARNING ● Do not remove the battery from the watch. ● If it is necessary to take out the battery, keep it out of the reach of children. If a child swallows it, consult a doctor immediately. ● Never short-circuit, tamper with or heat the battery, and never expose it to fire. The battery may burst, become very hot or catch fire. CAUTION ● The battery is not rechargeable. Never attempt to recharge it, as this may cause battery leakage or damage to the battery.
TO PRESERVE THE QUALITY OF YOUR WATCH WATER RESISTANCE ● Non-water resistant • If the watch becomes wet, have it checked by an AUTHORIZED PULSAR DEALER or SERVICE CENTER. ● Water resistant 5/10/15/20 bar 5 bar WR 10/15/20 bar WR • Do not operate the crown or buttons when the watch is wet or in water. If used in sea water, rinse the watch in fresh water and dry it completely.
* Pressure in bar is a test pressure and should not be considered as corresponding to actual diving depth since swimming movement tends to increase the pressure at a given depth. Care should also be taken on diving into water. ** We recommend that you wear a PULSAR Diver’s Watch for scuba diving.
SHOCKS & VIBRATION PERIODIC CHECK Light activities will not It is recommended that the affect your watch, but be watch be checked once 2-3 careful not to drop your every 2 to 3 years. Have Years watch or hit it against hard your watch checked by an surfaces, as this may AUTHORIZED PULSAR cause damage. DEALER or SERVICE CENTER to ensure that the case, crown, buttons, gasket and crystal seal remain intact.
STATIC ELECTRICITY The IC (Integrated Circuit) used in your watch will be affected by static electricity which may disturb the display. Keep the watch away from close contact with objects such as TV screens which emit strong static electricity. 16 LIQUID CRYSTAL PANEL The normal life expectancy for the liquid crystal panel of the watch is approximately 7 years. 7 Years After that it may decrease in contrast, becoming difficult to read.