Owners manual
6
New Construction/Extensive Remodel
“New Finished Wall Surface”
1. Prior to sheetrock, stub-out ½" hot and cold supply lines beyond nished wall surface, 4" on center.
The height of the Stub-outs is completely dependent upon desired mounting height of Leilani
ShowerSpa. For a person 5'8" – 6'2" we recommend the stub-outs be 37" from nished oor.¹
2. After nished wall surface has been completed, make certain water is completely turned off to both
hot & cold supply lines of Shower. Connect 90° male threaded ttings to stub-outs maintaining
¼" – ½" space between tting and nished wall. The open end of threaded male tting should
point down.
3. Mark location of holes for mounting bracket making sure bracket is level. For a person 5'8" – 6'2"
tall, we recommend 54½" from nished oor height². Before drilling holes for bracket, make certain
ShowerSpa will rest at against nished wall surface at desired mounting height with supply lines
connected.
4. Drill ¼" holes through wall surface using a masonry tile bit. Drill slowly through wall surface to
avoid cracking and chipping. Insert anchor and securely screw bracket to wall. Before connecting
hot and cold supply lines, mount ShowerSpa on wall, checking the height, and making sure
ShowerSpa feels secure.
5. Connect hot and cold water supply lines to male threaded pipe, do not over-tighten. Before
mounting ShowerSpa, check ttings to make sure they are secure. Turn on water and check for
leaks. When ttings are leak-free mount ShowerSpa on wall.
6. Optional: Seal around body of ShowerSpa with a bead of silicone. DO NOT SEAL BOTTOM.
¹ The desired mounting height of ShowerSpa determines height of ½" stub-outs. The stub-outs must
be located at a height allowing supply lines to be connected and body of ShowerSpa to rest at
against nished wall.
² This height may vary depending on several factors (i.e. location of supply lines, interference from
ShowerSpa plumbing, personal preference, etc.)
Retrotting An Existing Shower:
Note: In a re-model in which you are not replacing the nished wall surface (tile, or backing material)
it is advisable to purchase a PULSE ShowerSpa model that covers the location of existing valve
assembly- either single handle or two-handle type. If your PULSE ShowerSpa model does not cover
this area, you will need to either choose another PULSE ShowerSpa model that does or make
necessary repairs with appropriate materials (i.e. wallboard, tile, berglass, etc).
1. TURN OFF WATER SUPPLY TO SHOWER. (Note: Typically there is a gate valve where water
main enters the house. Turning the water valve off at hot water tank does not turn off cold water
supply line.)
2. Make certain water is completely turned off to both hot & cold supply lines of Shower. (Turn
shower valve on, both hot and cold, to verify water supply is OFF.) Open a sink faucet in the
bathroom in which you are installing ShowerSpa to relieve any pressure and help adequately
drain shower supply lines.
1. Shower Head ......................................Qty 1
2. ShowerSpa .........................................Qty 1
3. Slide Bar .............................................Qty 1
4. Hand Shower Holder ..........................Qty 1
5. Slide Bar Bracket ................................Qty 2
6. Slide Bar Cap .....................................Qty 2
7. Hand Shower ......................................Qty 1
8. Tapered End of Hose ..........................
9. Hand Shower Hose ............................Qty 1
10. Hexagon Nut End of Hose ..................
11. Machine Screw ...................................Qty 4
12. Lock Washer .......................................Qty 4
13. Rubber Washer ..................................Qty 1
14. Hose Washer ......................................Qty 2
15. ShowerSpa Wall Bracket ....................Qty 1
16. Coarse Thread Screw .........................Qty 2
17. Nylon Wall Anchor ..............................Qty 2
Parts Legend
3
Leilani ShowerSpa
Numbered Components
1
5
5
3
3
4
2
6
6
7
8
9
12
11
10
13
2
14
16
17
15
Wall Bracket Detail