Specifications

EMC-CS-2009.1
© Copyright Ford Motor Company – All Rights Reserved Page 35 of 121
February 11, 2010
Figure 11-2: RI 112 DUT Harness Configurations
3
3
4
+
_
1
10a
d
6
5
7 8
9
NC
1700 -0/+300
11
12
12
2
Ground Plane
3
3
4
+
_
1
d
6
5
7 8
9
1700 -0/+300
11
12
12
2
10b
Ground Plane
(a) DBCI (b) CBCI
Key:
1.
DUT 8. Current Monitoring Equipment (OPTIONAL)
2. Load Simulator 9. DUT Wire harness
3. Artificial Network
10a. DUT Power Return removed from wire harness and connected
directly to sheet metal. Wire length is 200 ±50 mm.
4. Automotive Battery
10b. DUT Power Return included in DUT wire harness
5. Injection Probe 11. DUT Case Ground (see section 11.3.1)
6. Monitor Probe (OPTIONAL) 12. Insulated Support (ε
r
1.4)
7. RF Generation Equipment
d = Injection probe distance from DUT (see section 11.4.2)