Figure 12-3: RI 140 Magnetic Immunity Test Setups for Helmholtz Coil
4
2
5
1
7
R
R >
5 cm
3
8
6
9
R
4
2
1
7
R
R >
5 cm
3
8
6
9
10
R
5
4
2
5
1
7
R
R >
5 cm
3
8
6
9
R
4
2
1
7
R
R >
5 cm
3
8
6
9
10
R
5
R > 50 mmR > 50 mm
R > 50 mmR > 50 mm
Configuration for Testing DUT only Configuration for Testing DUT
with attached Magnetic Sensors
Key:
1. Radiating Loop A
2. Signal Source
3. Current Probe
4. Measurement Receiver
5. DUT
6. Load Simulator
7. Radiating Loop B
8. Artificial Network
9. Ground Plane
10. Magnetic Sensor