Specifications

EMC-CS-2009.1
© Copyright Ford Motor Company – All Rights Reserved Page 51 of 121
February 11, 2010
Figure 13-1: RI 130 Default Test Setup
2b
1000 -0/+25
7
10
1
2a
> 200 mm
8
*
**
11
66
_
+
4
5
+
_
3
4
4
5
+
_
3
4
C
D
C
D
9
8
9
11
Detail
Key
1 DUT 7 DUT Monitor/Support Equipment
2a DUT Circuit Wire to be Tested 8 Coupling Test Fixture
2b DUT Wire Harness 9 Transient Generator (see Annex F for details). Generator
connected to Coupling test fixture via coaxial cable. Case of
generator connected to the ground plane.
3 Load Simulator 10 Ground Plane
4 Artificial Network 11 Digital Oscilloscope (1 GS/sec, 8 Mega sample)
5 Automotive Battery or linear power supply (Powers DUT
and Load Simulator)
* 1:100 high impedance probe (C < 4 pf) per ISO 7637-2.
Example: Agilent 10076A)
6 Automotive Battery (Powers Transient Test Generator) ** Current Probe (> 10 MHz, 30 A) Example: Agilent N2783A