Specifications

EMC-CS-2009.1
© Copyright Ford Motor Company – All Rights Reserved Page 56 of 121
February 11, 2010
15.0 Immunity from Continuous Power Line Disturbances: CI 210
The device shall be immune from continuous disturbances that occur on the vehicle’s low voltage (i.e. 13.5 VDC) electrical
distribution system. These requirements are applicable to the following component categories:
Electronic Modules: A, AM, AX, AY
Electric Motors: EM
15.1 Requirements
The devices shall operate in accordance to the requirements delineated in Figure 15-1.
Figure 15-1: CI 210 Requirements
0
1
10
0.01 0.1 1 10 100
kHz
U
S
(V
P-P
)
Functional Performance Status
Frequency Range (kHz) U
S
( V
P-P
)
Class A Class B Class C
0.05 – 1 0.2
1 – 10
f
2.0
10 – 100 2
I I I
f = frequency in kHz