Specifications

EMC-CS-2009.1
© Copyright Ford Motor Company – All Rights Reserved Page 62 of 121
February 11, 2010
Figure 16-4: CI 220 Test Setup Detail (Input Circuits with Remote External Pull-Up Resistor)
A
Tes t
Ground Plane
Ins ulator
Denotes Conn ection
To Ground Plane
A < 200 mm
Tes t
Fixture
Ground Plane
Denotes Conn ection
To Ground Plane
A < 200 mm
Tes t Puls e
Generator
DUT
Figure 16-5: CI 220 Test Setup for Application of Pulse G1
RR
Test
Fixture
DUT
DUT
Transient Pulse
Generator
R= 0.5 ohms
Figure 16-6: CI 220 Test setup for Application of Pulse G2
RR
Test
Fixture
DUT
DUT
Transient Pulse
Generator
Z
R= 0.5 ohms
"Z"
1
2
1
2
1. Zener diode: MR 2535L 2. Diode: 1N 5404
Diode configuration adjusted to yield voltage characteristics shown in Figure D-10 of Annex D.