User manual
Pulse Catch Input
Mode 50
UP Counters
Installation and
Safety Guidelines
7–6
Pulse Catch Input
DL205 High Speed Counter
Interface Manual, 2nd Ed, Rev. A
Custom Configuration
Up to this point, only Mode 50 default settings have been discussed. The default
settings will be suitable for many applications and will not require a custom
configuration. However, for those applications needing the defaults changed so the
D2–CTRINT will work for the applications, use the following table which contains the
options available.
Mode 50 Options
Point Number V-Memory
Location
Possibility (One per point) Hex Value
point 00
V7634
Pulse Catch Input 0005 (DL240/250–1/260) default
p
High Speed Interrupt (timed) ttt4 (ttt=1 to 999ms timer setting)
Discrete Filtered Input xx06 (xx=filter time)
High Speed Interrupt
(DL240/250–1/260)
0004
point 01
V7635
Pulse Catch Input
(DL240/250–1/260)
0005 (DL240/250–1/260) default
Discrete Filtered Input xx06 (xx=filter time)
High Speed Interrupt
(DL240/250–1/260)
0004
point 02
V7636
Pulse Catch Input
(DL240/250–1/260)
0005 (DL240/250–1/260) default
Discrete Filtered Input xx06 (xx=filter time)
High Speed Interrupt
(DL240/250–1/260)
0004
point 03
V7637
Pulse Catch Input
(DL240/250–1/260)
0005 (DL240/250–1/260) default
High Speed Interrupt
(DL240/250–1/260)
0004
Discrete Filtered Input xx06 (xx=filter time)
point 04 V7637 Not available in Mode 50 ––––