User Manual
9
NOTICE
1. The letter inside bracket [ ] is the variable code, which is able to be changed
2. The bracket [ ] is not included to the actual RS232 commands
3. Any dot “.” after the letters is part of the commands
4. ID coding:
• The ID codes of 40 Watt Power Amplifier ranges from 0 to F (hexadecimal), when
sending RS232 commands, please take notice of the address of the ID code
• If the address of the ID code is 0, any RS232 command is available
• If the address is in 1~F, it has one unique ID code (If the ID code is not the same with
the address, no RS232 command will work)
• While the ID code is in 1~F, please add “ID/” before sending the command
• For example, if the ID code is 5, the RS232 command needed is “604%”, the correct
command is in this format: 5/604%
• There is no need to add “ID/” before the command when the ID code is 0
Examples:
1. Switching the input 2 to the line out, the command is: 2A1
2. Turning up the volume of line audio, the command is: 603%
3. Preset the MIC volume to “21” degree, the command is: 521%
4. Checking the working status of 40 Watt Power Amplifier, the command is: 600%
5. If the ID code is 0, sending command 601% is able to turn up the MIC volume. If the ID
code is 2, sending command 601% will not work, and the MIC volume remains unchanged. The
right command is 2/601%