For vertical type permanent installationthe compressor should be bolted to the floor through
holes provided in the compressor feet Shims must be used to level the compressor before
bolting it to the floor Sever vibration will result when the compressor is bolted down tightly
and the feet are not level This can lead to welds cracking or fatigue of the air receiver
5.2
ELECTRICAL
It is your responsibility to ensure that the air compressor is electrically connected in a safe and
correct manner Any electrical work should be carried out by a competent electrician and
installed in a way which meets all applicable codes and regulationsA magnetic start must be
an integral parts of the air compressor except on contractor and professional series unitsA
magnetic starter may be supplied with your unit from the factory
Failure to connect the air compressor correctly to your buildings electrical services may result in
serious personal injury or damage to the equipment
Please note that under normal conditionsthe air compressor will operate intermittentlyShould
it be necessary to service that air compressor ensure the power source has been shut down
This must be down to prevent personal injury or damage to the unit
If the supply cord is damaged it must be replaced by the manufacturer or its service
agent or a suitable qualified person in order to avoid a hazard.
5-2-1
MOTOR
Wiring must be down in a manner that full voltage nameplate ±10% is available at the motor
terminals during startupUse of an incorrect electrical motor for your particular building
service will result in premature motor failure and is not covered by PUMA compressor or
motor manufacture’s warranty