Your compressor is ready for use
Before doing any maintenance or adjustments to your air compressorthe following safety
precautions should be taken
1
DISCONNECT ELECTRICAL POWER
2
DRAIN AIR RECEIVER OF AIR PRESSURE
8
MAINTENANCE CHECK LIST
8-1
Daily checklist
8-1-1
Check oil level
8-1-2
Drain condensation from air receiver tank
8-1-3
Check for any unusual noise or vibration
8-1-4
Be sure all nuts and bolts are tight
8-2
Weekly checklist
8-2-1
Clean air filter by opening air filter capReplace air filter if necessary
8-2-2
Check oil level and filling up if necessary
8-3
Quarterly or 300 hour checklist
8-3-1
Change compressor oil and filter element
8-3-2
Check condition and alignment of beltflywheel and motor pulley
Adjust belt tension if necessary or replace belt if worn
8-3-3
Check safety valve
8-3-4
Check pressure switch unloads to ensure compressor head unloads
whenever motor shuts down
8-3-5
Clean and blow off pump fins and motor
8-3-6
Inspect air system for leaks by applying soapy water to all jointsTighten joints
if leakages are observed
9
STORAGE
WHEN YOU HAVE FINISHED USING THE AIR COMPRESSOR
9-1
Set the “on/off” switch to “off” and unplug the cordially,
9-2
Be sure to drain the water from the air tank
9-3