2000W PRIMARY SUMP PUMP BACKUP POWER SYSTEM INSTRUCTION AND OPERATING MANUAL MODEL: BU-2000
GENERAL INFORMATION To ensure safe and reliable operation, please carefully read this service and installation manual in its entirety before installing and/or using this product. Reasonable care and safe methods in according with sound plumbing practices should be strictly adhered to. Before installation, refer to and understand all relevant local plumbing and electrical codes. DO NOT THROW AWAY THIS MANUAL. Keep it in a safe place so that you may refer to it for periodic service and maintenance.
PERFORMANCE The Primary Sump Pump Backup Power System will convert DC power from a 12VDC Deep Cycle Battery to AC power. When the Primary Sump Pump Backup Power System is inverting, the output waveform is a pure sine wave. SPECIFICATIONS ATTENTION The Primary Sump Pump Backup Power System is grounded via a PCB Ground Plane. This grounding technique is not detected by GFCI testing devices.
OPERATION When 120VAC household power is available to the Primary Sump Pump Backup Power System, household power is directly routed through to both of the outlet receptacles. When the unit is powered ON (the “Power” indicator LED will be BLUE), the unit will charge the connected 12VDC Deep Cycle Battery if needed. The “Charge” status indicator LED will be RED while charging the battery. The “Full” status indicator LED will be BLUE once the battery is fully charged.
INSTALLATION 1. Ensure the Backup Power System is powered off and disconnected from both AC and DC power. 2. Remove the Pre-Charge Kit from the positive (RED) battery lead ring. Open the Pre-Charge Kit and wrap one of the resistor wires around the positive (RED) battery lead ring. 3. Using the end not connected to the resistor wire, connect the positive (RED) battery lead to the positive (RED) terminal on the Backup Power System. Tighten the terminal retention knob securely by hand.
TROUBLESHOOTING WARNING Always disconnect the power unit from power sources before handling. This guide is designed to help identify reasons for potential operating problems. It is not a service guide. Dismantling of the Primary Sump Pump Backup Power System voids warranty. Servicing of power unit should be referred to PumpSpy. “FAULT” STATUS INDICATOR LED IS RED A RED “Fault” status indicator LED is a sign of system trouble. Make sure that the cooling fans are clear of any obstacles and debris.
LIMITED THREE-YEAR WARRANTY WHAT THIS WARRANTY COVERS When used and maintained in normal use and in accordance with the Installation and Operating Instructions, your PumpSpy® product is warranted against original defects in material and workmanship for a full three years from date of purchase (the “Warranty Period”). During the warranty period, PumpSpy will repair or replace at no cost to you, to correct such defects in products found upon examination by PumpSpy to be defective in materials or workmanship.