Use and Care Manual
LED STATES
POWER
Green
Red
AC Power is on
AC Power not available
SYSTEM
Green
Red
No current alerts
One or more alerts are active
DATA
Green Blink
Red Blink
System is connected to PumpSpy Remote Monitoring Service
System is NOT connected to PumpSpy
INFORMATION CENTER LCD MESSAGES
System OK Displayed when no alerts are active.
Power Fail
Displayed when no alerts are active.
Backup On/Pwr OK
Displayed when backup pump cycles with AC power available for primary pump. (Possible main pump failing)
Hi Water in Pit
Displayed when high water oat sensor is triggered.
Main FS Stuck On Displayed when primary pump runtime exceeds normal value.
Backup FS Stck On Displayed when backup pump runtime exceeds normal value.
Voltage Low
Displayed when battery voltage drops below 11.4 volts (50% discharged)
Voltage Critical
Displayed when battery voltage drops below 10.4 volts (90% discharged)
Primary Hi Amps
Displayed when primary pump current exceeds baseline amp reading by 50%
System Error
Displayed when alarm for an alert is muted.
Sig Strgth:xx
Display of signal strength as read from cellular module (press mute button)
Displayed when PumpSpy Monitoring Service initiates a system test
Reading Battery Displayed when unit measures battery voltage during self test
Displayed when system sends alert or self test results to PumpSpy
Host Data Valid Displayed when valid command is received from PumpSpy
© PumpSpy Technology, LLC Questions? Call Tech Support: 515.999.6935
Data > Host
Start Autotest
ALARM MUTE BUTTON
• Clears the alert message displayed on the information center LED
• Silences the alarm for 24 hours