Fountain Classic ™ Installation and Owner’s Manual Page 16 4120 NW 44th St • Lincoln, NE 68524 USA Tel: 402.467.9300␣ •␣ Toll Free in the USA: 800.875.5915 • Fax: 402.467.9393 www.purewaterinc.
Page 2 Fountain Classic Owner’s Manual
Table of Contents Important Safety Information ............................................................................................... 4 Introduction ........................................................................................................................................ 5 For the Record .................................................................................................................................. 5 Included With Your Distiller ......................................
Important Safety Information IMPORTANT: This distiller is designed to be used only with Pure Water, Inc. accessories and replacement components. Page 4 • If you are not sure that your electrical outlet is properly grounded or that the circuit protection is correct, have it checked by a qualified electrician. • Operate indoors only. • The area must be well ventilated. • WARNING: Disconnect from the power source before assembling, adjusting or servicing this appliance.
Introduction Congratulations on purchasing the finest water distillation system on the market. With proper care and attention, the Fountain Classic will give many years of top performance and high-quality drinking water. Please read this manual thoroughly before installing and operating your Fountain Classic. For the Record The model and serial number are found on the back panel. You should record all the necessary information below for future reference.
Getting to Know the Fountain Classic Photo Display Here 1 1. Photo Display Display—This is a backlit area to display photos or advertising. Several optional displays are available from Pure Water, Inc. or from your local distributor. 2. Water Dispensing Area Area—Three temperature units have dispensers for Hot Water, Room Temperature Water, and Cold Water and the two temperature unit has dispensers for Room Temperature Water and Cold Water. The Controls for these are listed in items 14 and 15. 3.
12. 13. 14. Post Filter Filter—The carbon filter enhances the flavor of the distilled water before it enters the storage tank. 11 Distilled Water Storage Tank Tank—This tank holds distilled water for use through any of the water spigots. This tank contains floats that turn the distiller off when full, and turns the distiller back on when the tank is 1/3 empty. 12 Water Dispenser Section Section—This section is composed of either two or three main sections, depending on your unit: a.
Installation CAUTION: CAUTION: NOTE NOTE:: NOTE NOTE:: NOTE NOTE:: DO NOT use a hot water line for the raw water supply. DO NOT turn the saddle tapping valve handle before or during installation. Be sure the piercing lance does not protrude beyond the rubber gasket. Failure to do this may result in damage to the piercing needle. The use of softened water for the raw water supply is recommended to minimize scale buildup in the boiling tank and drain valve.
6. Turn the saddle tapping valve handle clockwise until you feel it is firmly seated. Note: You have now pierced the copper tube and the valve is closed. 7. Turn the handle counterclockwise to open the valve. Turn the household water supply ON and check all connections for leaks. 8. Open the saddle tapping valve completely. Check the line for leaks. Tighten where required. Step 3 Plug the unit into an appropriate power plug: Locate the power cord in the parts kit bag.
Step 6 Steam Sterilization of the Machine: Use the high temperature tubing, included in the parts kit in place of the post filter. It will connect the outlet end of the condensing coil to the storage tank inlet. This tube must be used because the post filter cannot withstand the temperature of the steam. Now the boiling chamber is creating steam. The steam will rise up to the condensing coil. Normally the fan would cool the steam and it would change back to water form.
Maintenance Post Filter Changing and Steam Sterilization IMPORTANT: This tube must be used, because the post filter cannot withstand the temperature of the steam. Every 2000 operating hours (3 months if the unit is operating continuouly): Step 1 Empty the Distiller: It is very important that the storage tanks are empty before steam sterilization takes place. To do this: 1. Turn power OFF to the unit. 2. Turn the dispenser power OFF. 3. Turn the Dispenser Hot Tank Switch to OFF.
Step 4 Turn the dispensing unit on: 1. Allow the distiller to operate for an additional 5-6 hours. Several gallons of water will be in the storage tank. 2. Turn the Cooler Power switch to ON. 3. Turn the Dispenser Hot Water Switch to ON. (Three temperature unit only.) Cleaning the Boiling Chamber Every 2000 hours or every three months: Electrical Connection Step 1 Shutdown and Cooling: 1. Turn the distiller switch to the OFF position and unplug unit. 2. Allow the boiling chamber to cool down. 3.
Troubleshooting Guide Symptom Unit does not operate. Unit runs, but exhaust is cool. Water has bad smell or taste. Probable Cause Solution Unit not plugged in. Plug unit into power source. Power failure, circuit breaker or fuse blown. Reset breaker or replace fuse. Power switch OFF. Turn power switch ON. Heating element failure. Replace the heating element. Reset tripped. Push in the reset button. Post filter is depleted or carry-over problem. Replace the post filter.
Wiring Schematic Page 14 Fountain Classic Owner’s Manual
Exploded Drawing: 48998 Two Temperature Unit Fountain Classic Owner’s Manual Page 15
Parts List Key # 1 2 3 4 5 6 7 8 * 9 10 11 12 13 14 15 16 17 18 * 19 20 21 22 * 23 24 25 * 26 27 28 * 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 63 64 65 66 67 68 69 70 71 72 73 74 Key # Page 16 120V P/N 8009 6022 519 69 533 9085 402B 224-0003 406 9045 48003 9220 7230 7127 9041 7200 516 9030 8070 662 9082 9024 9080 6021 604 513 9018 9519 644 6005 9303 400A-02 727 9302 48018 7069 9079 9108 48502-02 9043 9314 9095 9316 7206 9018 9110 9023 9059 7228 723
Exploded Drawing: 48999 Three Temperature Unit Fountain Classic Owner’s Manual Page 17
Parts List Key # 1 2 3 4 5 6 7 8 * 9 10 11 12 13 14 15 16 17 18 * 19 20 21 22 * 23 24 25 * 26 27 28 * 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 120V P/N 8009 6022 519 69 533 9085 402B 224-0003 406 9045 48003 9220 7230 7127 9041 7200 516 9030 8070 662 9082 9024 9080 6021 604 513 9018 9519 644 6005 9303 400A-02 727 9302 48018 7069 9079 9108 48502-02 9043 9314 9095 9316 7206 9018 9110 9023 9059 7228 7232 219-022
Form #6338, ©2000, Pure Water, Inc. U.S.