Technical data

Function keys
F7
OK
The "OK" function key enters the data. If the module file
does not yet exist it is set up after confirmation.
F8
SELECT
If you press this key, a selection list is displayed with
possible entries for fields which cannot be edited freely.
Select entries from the list with the cursor keys and
enter them in the field with the return key.
Other keys:
(PC with stage V) BACKSPACE Displays a help text
(PC with stage VI) SHIFT F8
(PG) HELP:
RETURN
ENTER
INSERT: The values in the help window are entered in the input field.
ESC: Aborts the function - returns you to the basic screen
of the menu.
6.5.2 CP Init
The SYSID block edited with this screen contains all the initialization
parameters of the CP which are only adopted during system start-up, i.e. at
the transition from STOP to RUN or following power up. Modifications or
new entries in the SYSID block are therefore allowed only in the STOP
mode. Some parameters are processed in the SYSID block, others are only
used for management functions in the COM.
The SYSID block has the following tasks:
Uniform identification and assignment of the module within the SIMATIC
S5 system with SINEC L2.
Basics of Configuration B8976060/02
Volume 1 6 - 20