Technical data
N The CP 5430 TF/CP 5431 FMS receives synchronization frames if they
exist in the L2 network.
Sync cycle: 10 (sec) default
If the CP 5430 TF/CP 5431 FMS is the clock master, it sends clock
synchronization frames to the SINEC L2 network at the time intervals
specified above.
Possible values: 1 - 60 sec.
F7
OK
The data edited in the screen are entered as the
current data.
F8
SELECT
Activating this key displays a selection list for each
input field that cannot be freely edited. Values can be
selected in the list using the cursor keys and entered
directly in the input field with the return key.
13.3.1 Setting and Reading the Time in the
Programmable Controller
The CP 5430 TF/CP 5431 FMS has the job number 218 available for
processing the time.
A SEND with this job number writes the CP’s time, a RECEIVE, reads the
CP’s time.
These services are possible on the synchronized CP interfaces using the
standard HDBs for the PLC.
☞
When the CP starts up, internal test functions can lead to a
waiting time of 1 second before the clock can be read out
reliably from the PLC.
To provide the time for the programmable controller, the following
representation is used:
C8976060/02 Clock Services
13 - 9 Volume 1