Technical data
F2
SET
The time can only be set when the CP status is "master
clock" or "clock_slave_asynchronous" or when the clock
chip of the CP 5430 TF/CP 5431 FMS is marked as
invalid.
Displays in the COM 5430 TF/CP 5431 FMS screen
WEEKDAY: MONDAY - SUNDAY
DATE TODAY: e.g. 29. 10. 1993
The data can be set within the limits 01.03.1984 to
31.12 2083.
CURRENT TIME: e.g. 15:23:43
TIME DIFF-
ERENCE (1/2 H):
"+" or "-" and range between 0 and 24
CLOCK MASTER: Indicates whether the current CP 5430 TF/CP 5431
FMS is the clock master or is a clock slave.
CP CLOCK
STATUS:
CLOCK MASTER
the clock sends synchronization frames
CLOCK SLAVE
the clock receives synchronization frames
CLOCK SLAVE,+ INVALID
the clock must be set
CLOCK SLAVE,+ ASYNCHR
clock does not receive synchronization frames
SLAVE <--> MASTER
clock status change
TRANSMITTER ASYNCHR
time transmitter is itself asynchronous
SUBST SYNCHRON
the clock is synchronized from a CP 5430 TF/CP 5431
FMS
SYSTEM ERROR
an internal error has occurred
HW CLOCK FAILURE
hardware clock has failed
Clock Services C8976060/02