Technical data

With the TERMINATE command of this utility, or by calling a different
PATH, you can terminate a dedicated link again.
Example of a Path::
PG-->COR/MUX-->CP 5430 TF-->CP 5430 TF-->COR/MUX-->ENDP
15.1.2 Editing a Path
The method of editing a path is described in the manual for your PG under
the utility "BUS SELECTION". Here, the procedure for the paths
represented in Figs. 15.2 and 15.3 will be illustrated.
Path_1: (PG via AS511)
Set the AS 511 interface in the PG
Call the bus selection package
Specify the path name and path file (this combination later selects the
node in the application programs e.g. LAD/CSF/STL, NCM)
Edit and store the path
Check the path by attempting to activate it
Path_2: (PG via internal L2 interface)
Set the L2 interface in the PG
Call the bus selection package
Specify the path name and path file
Edit and store the path
Check the path
Utilities B8976060/02