Installation manual

15
PureFlow AirDog
AirDog® 100 & 150 Dodge Cummins 1994 - 1998
Section 5-D Fuel Suction Line
Fuel Suction Line for AirDog
®
FP-100!
NOTE: The AirDog
®
FP-150 requires a High Flow Suction Tube. If you are installing an
AirDog
®
FP-150 skip Section 5D and go to section 5E for these installation instructions!
Connecting the Fuel Suction Line from the Tank to AirDog
®
FP-100
Figure 34 Figure 35
5D-1. Insert the female connect end (see figure 36) of the “Suction Hose Assembly” to the
male quick connect fitting previously installed in the “Fuel In” port. A “click” will be
heard when the fitting is properly connected.
Figure 36
5D-2. Remove the original fuel suction line Quick Connect fitting from fuel tank by squeezing
the tabs on the end of the connector together. Consult factory manual if unsure.
Suction Tube
Quick Connect Fitting
View From Beneath Bed
Figure 37 Figure 38 Figure 39
In More Detail
To release the quick-connect fitting from the fuel tank suction tube, push the fitting
toward the suction tube while firmly holding the plastic retainer ring into the fitting.
With the plastic ring firmly depressed, pull the fitting assembly from the suction tube.
Use care to hold the retainer ring square to the Quick Connect Fitting body. It may be
difficult to disconnect the fitting if the retainer is cocked or becomes cocked during
removal.
Fuel Return Tube