CAT5e Cable Termination (for CAT5e Input/Output Boards)
PM series CAT5e (HDBaseT) extenders are designed TIA/EIA-566-B Standard. Please
ensure that each PIN layout of the cable is corresponding with the picture below before
connecting the cable. Please note that CAT5e or above level cable enables to deliver better
quality and longer distance.
RS-232/422 Cable Termination
5-pin Phoenix connector is used for RS-232/422 communication between PM extender
Tx/Rx to the devices that are attached.
* Pinout from the left
Pin
TIA/EIA-568B Signal
Wire color Digital RGB
1 Orange/ White TMDS Data2+
2 Orange TMDS Data2-
3 Green/ White TMDS Data1+
4 Blue TMDS Data0+
5 Blue/ White TMDS Data0-
6 Green TMDS Data1-
7 Brown/ White TMDS Clock+
8 Brown TMDS Clock-
Pin RS-232 RS-422
1 Tx Tx +
2 Not used Tx -
3 Ground Ground
4 Rx Rx +
5 Not used Rx -