User`s guide

www.purelink.de
8
Section 3: Notice
1. All HDMI over CAT5 transmission distances are measured using Belden 1583A CAT5e 125MHz UTP
cable and ASTRODESIGN Video Signal Generator VG-859C & VG-870B.
2. Incorrect placement of IR Blaster and Receiver may result in the failure of the IR extenders. Please
check carefully before plugging in the IR extender to the respective IR sockets. Warranty will not
cover the damage.
3. The transmission length is largely affected by the type of Cat-5/5e/6 cables, the type of HDMI sources,
and the type of HDMI display. The testing result shows solid UTP cables (usually in the form of 300m
[1,000ft] bulk cables) can transmit a lot longer signals than stranded UTP cables (usually in the form
of fixed length patch cords). Shielded STP cables are better suited than unshielded UTP cables. A
solid UTP Cat-5e cable shows longer transmission range than stranded STP Cat-6 cable. For long
extension applications, solid UTP/STP cables are the only viable choice.
4. EIA/TIA-568-B termination (T568B) for Cat-5/5e/6 cables is recommended for better performance.
5. To reduce the interference among the unshielded twisted pairs of wires in Cat-5/5e/6 cable, one can
use shielded STP cables to improve EMI problems, which is worsen in long transmission.
6. Because the quality of the CAT5/6 cables has the major effect on how long the transmission limit can
achieve and how good is the received picture quality, the actual transmission range is subject to one’s
choice of Cat-5/5e/6 cables. For desired resolutions greater than 1080i or 1280x1024, a Cat-6 cable
is recommended.
7. If your HDMI display has multiple HDMI inputs, it is found that the first HDMI input [HDMI input #1]
generally can produce better transmission performance among all HDMI inputs.
Section 4: Performance Guide
Performance rating
Type of CAT5/6 cable
Wiring
Shielding
CAT5
CAT5e
CAT6
Solid
Unshielded (UTP)



Shielded (STP)



Stranded
Unshielded (UTP)


Shielded (STP)

Termination
Please use EIA/TIA-568-B termination (T568B) at any time