User`s guide

www.purelink.de
11
Operation
Procedure
VFD Window
Mute Output
Mute + A~H(Output 1~8) + Take
Ex: Mute Output 3
1. Press “MUTE” button
Mute A~H Take
OUTPUT: -
2. Press number key “Cto select Output 3
Mute A~H Take
OUTPUT: 3
3.Press “TAKE” button
Port : 1234
Source: 2202
Output Status
Status + A~H(Output 1~8) + Take
Ex: Output 4
(Input 2)
1.Press “STATUS” button
Status A~H Take
OUTPUT:- IN:-
2.Press number key “D” to select Output 4
Status A~H Take
OUTPUT: 4 IN:-
Status A~H Take
OUTPUT: 4 IN:2
3.Press “TAKE” button
Save Current
Mapping
Save + A~H(1-8 storage site) + Take
Ex: Save current
mapping to 5
1.Press “SAVE” button
Save A~H Take
Save(1~8): -
2.Press number key “E” to select the storage site 5
Save A~H Take
Save(1~8): 5
3.Press “TAKE” button
Save A~H Take
Save(1~8): 5
Preset Mapping
Preset + A~H(1-8 storage site) + Take
Ex: Preset saved
mapping from 5
1.Press “PRESET” button
Preset A~H Take
PRESET(1~8):-
2.Press number key “E” to select the storage site 5
Preset A~H Take
PRESET(1~8): 5
3.Press “TAKE” button
Preset A~H Take
PRESET(1~8): 5
Learn default EDID
Default EDID + A~H (1-8 storage site)+
1~VIII(input 1~8) + Take
Ex: Default EDID 2
Input 3
1.Press “DEFAULT EDID” button
DefA~H ~VIII Take
from : - to IN:-
2.Press number key “B” to select default EDID 2
DefA~H ~VIII Take
from : 2 to IN:-
3.Press number key “” to select Input 3
DefA~H ~VIII Take
from : 2 to IN:3
4.Press “TAKE” button
DefA~H ~VIII Take
from : 2 to IN:3
Learn EDID Port
EDID
Learn + D(EDID Port) +~VIII (input 1~8) + Take
Ex: Learn EDID Port
Input 3
1.Press “LEARN” button
OUT A~D ~VIII Take
From : 0 to IN:0
2.Press number key “D” to select EDID Port
OUT A~ D ~VIII Take
From : 4 to IN:0
3. Press number key “” to select Input 3
OUT A~ D ~VIII Take
From : 4 to IN: 3
4.Press “TAKE” button
OUT A~ D ~VIII Take
From : 4 to IN:3