Multipure ® Multipure Drinking Water Systems Aquaperform Owner's MAnuAl For Model Nos. MP880SC, MP880SB, MP880SI and MP880EL Please retain this manual for future reference. Multipure International l P.O. Box 34630 l las Vegas, nV 89133-4630 l Phone 702.360.8880 l Toll-Free 800.622.9206 www.multipure.
Multipure Drinking Water Systems Thank you for selecting a Multipure Drinking water system to meet your need for quality drinking water. You have acquired one of the finest drinking water treatment devices available for the reduction of a wide array of contaminants. we are confident that your Multipure system will make a difference in your life. Thank you for your business.
About the Aquaperform Drinking Water System • • • The Multipure Aquaperform Drinking water system (Model# MP880) is designed for use on the countertop next to the sink, below the sink, or inline with other devices. It can connect to the existing faucet or to the water source below the sink. The Aquaperform includes all the accessories and fittings required for installation (except for the MP880sI Inline unit).
Below Sink Installation Overview & Part Numbers Item # Part # Part Description Item # Part # Part Description 1 MC652 2 3 MC780 MC720 4 MC720 8 9 10 11 12 13 MC253AsBl MC126 MC351 MCB7.
Countertop Installation Overview & Part Numbers Diverter Valve Part Numbers 1. 2. 3. 4. 5. 6. 7. 8. 9. MC6400AsBl MCl500 MC252-BlK MC253AsBl CB11As MC351 MCB7.
1. INSTALLATION PREPARATION Before beginning, inspect your Dws to confirm that it has been received in good condition and that all parts are included (refer to the specific installation section for the parts list). Perform the following instructions prior to system installation. should you require assistance, please contact your Independent Distributor; if she/he is not able to help you, please feel free to contact Multipure's Customer service Department directly at 800.622.9206. Model MP880SB 1.
1.2: Locating the Appropriate Installation Instructions 1. 2. 2. Determine your installation type (e.g., countertop, below sink, inline). Proceed to the instructions for your installation type: a. For Countertop Installation, proceed to section 2. Countertop Installation. b. For Below sink Installation (with or without a capacity monitor), proceed to section 3. Below Sink Installation. c. For Inline Installation, proceed to section 3.6: Installing the System for Inline Use.
2.2: Preparing and Operating Your Drinking Water System 1. using a paper towel or cloth, dry off all connections and the Dws housing. 2. Make sure that all connections are tightly secured. 3. Purge any air from the unit. a. Press the right button on the diverter valve to select the filtered water spout. The water will flow through the Dws and emerge from the smaller opening on the diverter valve. b. Allow water to flow through the Dws and filtered water spout for five minutes. c.
3.2: Installing the Faucet The Aquaperform faucet can be installed through a standard faucet hole or spray hose hole in your sink, if one is available. If no hole is available, refer to section 3.2-a: Drilling the Faucet Hole. note that there are separate sections for installing a faucet with or without a capacity monitor. Proceed to the instructions for your installation type: 1. For a standard faucet, proceed to section 3.2-b: Installing the Standard Faucet. 2.
3.2-b: Installing the Standard Faucet Complete Faucet Assembly with Blue Tubing MC652 small black washer Cover Plate large black washer COUNTERTOP Plastic Washer Lock Washer Wing Nut Blue Tubing NOTE: The blue plastic tubing is attached to the faucet. 1. From the sink / countertop: a. Place the larger soft black rubber washer over the faucet hole. b. Place the cover plate on top of the large washer. c. Place the smaller soft black rubber washer on top of the cover plate. d.
3.2-c: Installing the Capacity Monitor Faucet when the Aquaperform is installed with a capacity monitor, the DigiFlow 5000V Capacity Monitor (MC993) flashes red when the filter should be changed. Two AAA batteries (not included) are required for capacity monitor operation. The Capacity Monitor consists of two main parts, the leD Display Plate that sits below the faucet, and the Filter Monitor unit (FMu) that connects in-line between the drinking water system housing and the faucet.
3.2-c: Installing the Capacity Monitor Faucet (continued) Connect the Tubing to the Filter Monitor Unit Capacity Monitor Assembly nOTe: Complete this step only after the Dws tubing has been connected in section 3.4: Connect the Tubing to the Housing. 1. 2. 3. 4. Connect the two tube fittings (#15) (MC744) to the Filter Monitor unit (#14) (FMu) by threading them into the threaded ports, one on each side (tighten securely, but do not over-tighten).
3.2-c: Installing the Capacity Monitor Faucet (continued) Reading the LED Display Plate 1. when you turn on the faucet, or when the button on the FMu is pressed, the leD on the leD Display Plate blinks five (5) times to indicate the filter capacity status. The color of the leD indicates the filter status: a. Green = 30% - 100% filter capacity b. Orange = 0% - 30% filter capacity c. red = 0% filter capacity (the FMu will also play a long audible sound to indicate 0% capacity) 2.
Adapta Valve Installation (continued) 1. using the 3/8” configuration: a. The 3/8” configuration is used on a water supply line with a 3/8” slip joint. b. The 3/8” configuration is typically installed at the bottom of the riser at the angle stop valve. 2. using the 1/2" configuration: a. The 1/2" configuration can be used at either the top of the riser at the faucet pipe or at the bottom of the riser at the angle stop valve. b.
3.4: Connecting the Tubing to the Housing OuTleT Attach the Adapters to the Housing InleT 1. Connect the included Inlet adapter (MC720) to the system housing’s labeled Inlet port. rotate the adapter clockwise, first by hand, then using a wrench, to tighten onto the system. 2. Connect the included Outlet adapter (MC720) to the system housing’s labeled Outlet port. rotate the adapter clockwise, first by hand, then using a wrench, to tighten onto the system.
Connecting to an Icemaker, Instant Hot Dispenser, or Other Device use the following steps to connect the Dws to an icemaker, instant hot dispenser, or other device in addition to your faucet or capacity monitor faucet. A Tee adapter (MC445) is required. nOTe: To connect your Dws to the icemaker, instant hot dispenser, other device, you must have access to this other device from your sink. Blue tubing 1.
3.5: Placing the System Under the Sink The Aquaperform models MP880sB and MP880el are designed to mount to the cabinet wall beneath the sink. These systems can also sit on the cabinet floor with the use of an optional acrylic base. If you would like to order the Aquaperform acrylic base, please contact Multipure Customer relations at 800.622.9206, ext. 175. nOTe: The Aquaperform Dws weighs approximately 7.5 lbs. with a dry filter; the system weighs more when the filter is wet.
3.6: Installing the System for Inline Use Multipure Inline models are ideal for refrigerators, water coolers, or restaurants where all water to a cold water outlet or faucet is filtered. Model MP880sI includes the housing, filter, bracket, and screws. The inline models are appropriate for an inline installation and can be used with your existing faucet. It is recommended that the inline models be installed by a professional plumber in accordance with established plumbing procedures. 3.
4. Maintenance 4.1: Regarding Filter Capacity 1. exact filter capacity varies in proportion to the amount of water used and the level of impurities in the water being processed. For contaminants reduced through physiochemical adsorption, the filter capacity is 600 gallons. For contaminants reduced through mechanical filtration, capacity claims are inapplicable due to broad variations in the quality and quantity of physical matter in the drinking water.
4.4: Resetting the Capacity Monitor or Changing the Batteries Resetting the Capacity Monitor After changing the drinking water system filter, the capacity monitor must be reset to its original capacity. 1. Press and hold the check/reset button on the Filter Monitor unit (FMu) for three (3) seconds. You should hear a long audible sound. 2.
5.2: Performance Certifications Multipure Drinking Water Systems Product Performance Tested and Certified Multipure Drinking water systems have been tested and certified by nsF International to comply with nsF/AnsI standards 42 and 53 for the reduction of specific contaminants being considered as established or potential health hazards.
5 . 3 : P e r f o r m a n c e D a ta S h e e t Performance Data Sheet Multipure Drinking water systems have been tested and certified under nsF/AnsI standard 53 as shown below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in nsF/AnsI 53, Health effects. For Model Nos.
5 .
5 . 3 : Performance Data Sheet (continued) NSF/ANSI 42 - Aesthetic Effects The system has been tested according to nsF/AnsI standard 42 for the reduction of the following substances. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system. note: This addresses the u.s.
5 . 4 : California Certification Department of Public Health Facts About Arsenic (in compliance with nsF standard 53) Arsenic (abbreviated As) is a naturally occurring contaminant found in many ground waters. Arsenic in water has no color, taste, or odor, and must be measured by lab testing. Public water utilities must have their water tested for arsenic, and their results can be obtained from your local water utility.
5 .
5.
Be sure to replace your filter at least once a year or sooner, if needed. Date of Installation:________________________________________ Unit Model Number:_______________________________________ Filter Type:______________________________________________ Dates of Filter Change To order a Replacement Filter Call 800.622.9208 or www.multipure.com/rf.htm Multipure 7251 Cathedral rock Drive las Vegas, nV 89128 800.622.9206 toll-free 702.360.8880 phone 702.360.8575 fax headquarters@multipure.