User Guide WMTS 105 Certificate No. 23291 Pro-Switch OCT2022 Sparq S6 Sparkling, Chilled & Hot Water Filter System For correct operation & installation, it is essential to observe these instructions.
What's Inside What's Inside Puretec Customer Service ...........................................................................................................................3 Installation Record ...........................................................................................................................................3 Before Installation.............................................................................................................................................
Introduction Puretec Customer Service Thank you for purchasing a Puretec Sparq S6 Drinking Water Appliance. The Sparq S6 is a proven performer manufactured from only quality materials and components. It will give years of reliability and trouble-free operation if maintained properly. Caution: Do not use with water that is microbiologically unsafe or without adequate disinfection before or after the system. The Puretec Sparq S6 is designed for metropolitan supply water only.
Before Installation Before Installation VERY IMPORTANT! Carefully read through this instruction booklet and check that all requirements can be met. Faulure to meet requirements may result in voided warranty. • Check the mains water pressure is between 138 - 500kPa. Note: Where maximum line pressure exceeds 500, the supplied multivalve must be installed to comply with Australian Plumbing Standards. • The Sparq S6 system is designed for mains/towns warter supply only.
Parts Included Parts Included Unpack the equipment. Ensure all parts are present and have not been damaged in transport.
System Identification Figure 1 - Dimensions 290 mm 93 mm 230 mm min. 150 mm air gap 110 mm 405 mm 350 mm (Coloured) & 345 mm (Chrome) 197 mm A Ø26mm hole is required for faucet (Max. 30mm).
System Identification Figure 2 - CO2 Bottle Pressure Gauge Pressure Regulator CO2Tube (Black) CO2 Bottle TOP VIEW Pressure Gauge Pressure Regulator CO2 Bottle SIDE VIEW Copyright © Puretec Pty Ltd 2022 Puretec Sparq S6 User Guide 7
Ventilation Figure 3 - Clearance Envelope Warm air OUT via buffer pad gap. 550 mm Clearance Envelope 50 mm 50 mm Warm air IN via cabinet floor cutout or kickboard ventilation grille. NOTE: Clearance at the back of the until from the wall needs to be 150 mm.
Ventilation Figure 4 - Buffer Pads & Floor Air Gap Upper cabinet rail sits flush with cabinet door. No air gap. Standard cabinet floor in contact with door. No air gap. Buffer pads installed to create air gap. and allow warm our OUT. A. Cabinet floor cutout to enable cool air IN. Ventilation For air flow cutouts a drill and jigsaw, keyhole or wall board saw will be required.
Ventilation Cutouts HINT: First mark & drill pilot holes in each corner of the required cutout, finishing cutout with a jigsaw, keyhole or wall board saw. To allow the cool air to be drawn into the cabinet, cut out the cabinet floor as shown in Fig. 4 and Fig. 5 (A. Cabinet Floor cutout). Ideally this should be as large as possible along the cabinet for maximum ventilation. Alternatively, a ventilation kit (not included) can be installed by cutting out a hole for a kickboard ventilation grille (see Fig.
Exploded Diagram Figure 6 - Exploded Diagram Sparq Faucet Straight Connector Wiring Loom Hot Water Line (Silicone Tube) Water Outlet (White) CO2 Tube (Black) HOT Water Inlet (Cold Line) SmartTee™ Tap WATER OUT DRAINAGE WATER IN CO2 IN Multivalve (Pressure Limiting Valve) Unit Power Supply Z1 Filter Cartridge & Mounting Bracket Water Inlet Connection (Blue) Note: All cold water lines are 1/4" tube.
How To Operate The Tap How To Operate The Tap When the blue light is on, the tap is in 'Sleep Mode'. Press any button once and the LED light will change from blue to green to indicate that the tap is ready. Press the button again to start dispensing water. ECO Mode Temperature Hot Water Temperature Override Press the setting button once to override 80°C or 90°C degree setting as a once off for unit to heat water to 100°C degrees.
Quick Connect Fittings Note: • Eco mode activates after 10 minutes from lights out. • Under bench module lights deactivate. • Hot side powers down, cold and sparkling maintain chilled function. • Hot water Temp lights deactivate (80, 90, 100). • Dispenser icons remain illuminated. • Dispenser icons will still dispense water when depressed (hot will not be hot however). • Unit will begin heat cycle 1 min after room lighting is sufficient with tap lights and unit lights re-illuminating.
SmartTee™ Figure 8 - SmartTee™ Quick Connect Fitting 1. Turn the quick connect nut on the SmartTee™ anticlockwise to release the collet. 2. Cut the tube square and push into into the tube stop (inside the collet). For metal tube; remove burrs and chamfer tube end to prevent O-ring seal being damaged. 3. The fitting grips before it seals. Ensure the tube is pushed all the way into the tube stop. 4. Once the tube is secured in position, turn the quick connect nut clockwise to secure.
Installation Installation VERY IMPORTANT! The following installation sequence must be followed in the correct order and as specified in this userguide by suitably qualified tradespeople. The unit and CO2 Bottle must be installed upright (as depicted within this user guide) In the event of a leak or electrical fault, the unit must be isolated from both power and water. Advice should be sought out by the relevant licenced tradesperson.
Installation 9. Choose the best position for the unit with the required 150 mm clearance for ventilation to the rear and top of the unit and in a suitable place where water spillage will not cause damage. 10. Select a suitable location for the Z1 Ultra Z Filtration System that is close to the unit.. Note: Remember to allow access room for changing the filter and a suitable place where water spillage will not cause damage. Location should not be in direct sunlight. 11.
Commissioning 20. Connect the CO2 bottle to the regulator by screwing the regulator clockwise onto the bottle firmly, but taking caution not to overtighten as this may cause the sealing rubber to perish and leak. Use soapy water on the connection between the bottle and regulator to test for leaks. Note: Some CO2 will escape as the valve in the bottle is depressed during connection. 21. Attach one end of the black tube to the regulator (See Fig.
Commissioning Chilled & Sparkling Water Commissioning 1. Ensure the CO2 bottle is connected firmly to the regulator and the black gas tube is fitted correctly. 2. Slowly open the CO2 regulator by turning the black knob clockwise (+) until the gauge reads 3 Bar. 3. Turn off the water supply at the inlet (SmartTee™ valve). 4. Purge the soda water line of any air by pressing on the sparkling button on the tap for 30 seconds.
Gas Replacement Gas Replacement - As Required 1. Isolate the CO2 by turning the black knob fully counter-clockwise (-) until home. 2. Unscrew the depleted CO2 bottle from the regulator. (Turn the empty CO2 bottle clockwise). Note: Some CO2 may escape as the valve in the bottle is depressed. 3. Connect the new CO2 bottle to the regulator by screwing the bottle counter-clockwise onto the regulator firmly, but taking caution not to overtighten as this may cause the sealing rubber to perish and leak.
Filter Replacement Filter Cartridge Replacement - Every 12 Months or When Taste Returns 1. Place a container or towel under the filter to catch any drips. 2. Isolate the water supply at the SmartTee™ and release water pressure by operating the cold button on the tap. 3. Rotate the old cartridge counterclockwise 1/4 turn, pull it out and dispose of it. 4. Remove all packaging from the new cartridge, including any wraps or caps (if applicable). Replacement cartridge Z1-R 5.
Troubleshooting Troubleshooting SYMPTOMS POSSIBLE CAUSE POSSIBLE SOLUTION No cold water. Cold temperature switch is off. Please turn the cold temperature switch on. Refrigerant is low. Call your service provider. Problem with compressor or thermostat. Call your service provider. Ice blockage. Please turn off the power supply and allow 24 hrs for the blockage to melt. No water inside the cold water tank. Please check mains water supply. CO2 bottle is empty. Replace CO2 bottle.
Warranty WARRANTY Any claim under this warranty must be made within 2 years of the date of purchase of the product. This product is warranted to be free of defect of material and workmanship for 2 years from date of purchase. Puretec is renowned for its quality and after-sales support so if you have any issues please call 1300 140 140 (AU) or 0800 130 140 (NZ). To make a warranty claim, contact us directly or the place of original purchase.
Warranty WARRANTY / AUSTRALIA This warranty is given by Puretec Pty Ltd, ABN 44 164 806 688, 37-43 Brodie Road Lonsdale SA 5160, telephone no. 1300 140 140 and email at sales@puretec.com.au. This warranty is provided in addition to other rights and remedies you have under law: Our goods come with guarantees which cannot be excluded under the Australian Consumer Law. You are entitled to replacement or refund for a major failure and to compensation for other reasonably foreseeable loss or damage.