Released on 1-May-14 – X800058P Page 12 UV Pure Technologies Inc. © 2014
Do not over tighten. Keep the coil of the valve pointing upward (to prevent
water from dripping on it). Water will not flow backwards through the valve.
WOOD TO RISE
ABOVE UNIT
WOOD TO FALL
BELOW UNIT
INCORRECT
MOUNTING MOUNTING
CORRECT
MOUNT UNIT FLAT
AGAINST PLYWOOD
ON A WALL
OR
Figure 1D
Step 4: Connect the solenoid valve to the Stainless flexible hose attached to the
bottom of the Hallett. Do not bend the hose excessively. Make sure the sealing
washer is inside the end of the hose before making the connection. The solenoid
valve plugs into a polarized plug at the bottom of the front cover near the power
cord. The valve is a non-serviceable component and nothing else should be
plugged into this port. Secure the cable from the valve to the wall. The solenoid
valve is normally closed and must be powered to open. The valve has a manual
override (white lever) that can be used to force the valve open should you require
water for service/emergency purposes (note in the event of alarm and shut down
it is recommended you boil your water). In any regulated sites such as
municipal applications, the manual override should not be used. For normal
operation, always leave valve in automatic position. Test the valve monthly to
confirm valve opens and closes. Unplug valve from unit to confirm water stops
flowing.
Caution: Do not allow solder or solder flux to fall in or on the unit.
Step 5: Connect the remaining piping to the top Stainless flexible hose at the top
of the unit. Do not use PVC pipe or braided hose at the outlet – during periods
of no flow, water temperatures may exceed softening point of PVC. Metal pipe or
high temperature plastic pipe such as PEX, should be used after the flexible
hose. Make sure the sealing washer is inside the end of the hose before making
the connection. Do not bend the flexible hose excessively. Tighten securely.