Released on 1-May-14 – X800058P Page 14 UV Pure Technologies Inc. © 2014
Min. 12"
[30cm]
SOLENOID
VALVE
OPTIONAL
DRAIN
MANUAL SHUTOFF
VALVE - ESSENTIAL
CHECK VALVE
ESSENTIAL
TYPICAL INSTALLATION OF PARALLEL UNITS
MANUAL SHUTOFF
VALVE - ESSENTIAL
GROUNDED
OUTLET
120VAC/60 Hz
PURGE VALVE OPTION
(2 PLACES)
TO
DRAIN
5 MICRON FILTER
20" "BIG BLUE"
(OPTIONAL)
Figure 1E
Flushing Instructions
Flushing the system is required after installation or after any disassembly and
cleaning. Flushing may also be required to remove colored water from the unit.
Most filters (if installed) also require flushing prior to use – follow the
manufacturer’s recommendations.
The system may be flushed in two ways. It can be done manually by
disassembling the unit and filling and draining the unit by hand (see Cleaning the
Unit). Flushing may also be done while the unit is operating. Plug in the unit and
open a faucet closest to the unit and run the water for a minimum of 5 minutes.
External Alarm Contacts
The Hallett system provides an external “dry” contact for remote alarms or
autodialers – the word “dry” indicates no voltage present at the contact. It can be
wired normally open or normally closed. The contact is referred to as a “System
Run” condition. The status of the contact changes when the Hallett unit changes