Step 2: Loosen the screws and remove the top and bottom covers.
Step 3: Remove the lamps (see Replacing UV Lamps). Keep the lamps in a safe
place.
LOOSEN SCREWS
HALLETT 30
Figure 4A
Step 4: Remove the side cover panels by loosening the two screws on the top
fold. On the newer Hallett 30s, the reflectors are held in place by a U-clip and
pins. First remove the U-clip from both sides, the remove the back reflector by
gently pushing the tab out from the alignment pins. To remove the front reflector,
the UV sensor can be removed. If the left lamp is removed, the front reflector can
be manipulated out leaving UV sensor in place.
Step 5: Examine the quartz sleeve both inside and out. If it is clean, no
disassembly is required. Replace the reflectors &/or side panels, lamps and
covers. Plug in the unit and operate as normal. If the quartz sleeve is dirty on the
outside, proceed to wipe it down with a clean lint-free cloth and rubbing alcohol to
remove the dirt. If the quartz sleeve is dirty on the inside, proceed with in-place
cleaning or disassembly.