Pipe insulation is provided to wrap around the top hose coming out from
the unit. Any other piping overhead must also be wrapped to prevent
condensation from dripping back onto the unit.
Note: Teflon tape and thread sealant are not required to connect the Stainless
flexible hoses to the Hallett or to the plumbing system – the FIP connectors mate
with male NPT (National Pipe-Taper) fittings. The rubber washer in each end of
the hose provides the seal. Ensure that the washer is in place before making the
connection.
Tools Needed
pipe cutter, torch and other typical plumbing tools for modifying piping
Wrench for tightening hose connections
Phillips screwdriver
Slotted screwdriver
Do not operate a unit that has been damaged or that is missing any components.
If a part is missing from your Hallett, contact your dealer.
The installation of the Hallett (see Figures 1A through 1E) should be done in
compliance with all applicable federal, state/provincial, and local regulations. We
recommend that the unit be installed by a qualified service technician. Failure to
install the system properly may result in property damage (leaks/flooding) or
personal injury (electrical shock).
Location
The unit must be positioned vertically on a wall (the performance of the
system will be adversely affected if mounted horizontally) with the following
clearances:
Hallett 30 (See Figure 1A and 1D)
21" (53 cm) above the unit for lamp replacement
12" (30 cm) minimum below the unit for service access
7" (18 cm) on each side of the unit for service access
The Hallett is intended only for indoor use in a dry location. The unit should not
be installed in any drafty areas (that could affect the temperature requirements
see pre-treatment requirements page 6). Should these minimum installation
recommendations not be met, the system will not operate effectively.
The Hallett should be installed downstream of any pre-treatment devices such as
filters, water softeners etc and also any pressure tanks. However, it must be
installed upstream of any branches in the piping so that all the water is
disinfected before splitting and distributing throughout the home or facility. The
Hallett unit must be upstream of any chlorine injection system. Warning: If
connection is made to a potable water system, the system shall be protected
against backflow.
Time Required
Please note that full installation of the Hallett requires shutting off the main water