Use and Care Manual

Introduction Installation Maintenance Troubleshoot WarrantySafety
Inuent Challenge
Concentration
*(mg/L unless specied)
0.03 ± 10%
0.3 ± 10%
0.15 ± 10%
750 ± 40 mg/L
Substance
Cadmium
Chromium (Trivalent)
Lead
TDS (Total Dissolved Solids)
Average Percent Reduction
(%)
99.2
96.0
99.1
91.2
*Maximum Permissible Product
Water Concentration
(mg/L unless specied)
0.005
0.1
0.050
187
Performance Data
PL400G system tested and certied by WQA to NSF/ANSI 58 for cadmium, trivalent chromium,
lead, and TDS, and NSF/ANSI 372 for low lead, as veried and substantiated by test data.
This system has been tested according to NSF/ANSI 58 for reduction of the substances listed
below. The concentration of the indicated substances in water entering the system was reduced
to a concentration less than or equal to the permissible limit for water leaving the system, as
specied in NSF/ANSI 58 standards. While testing was performed under standard laboratory
conditions, actual performance may vary.
This reverse osmosis system contains a replaceable component critical to the eciency of the system.
Replacement of the reverse osmosis component should be with one of identical specications, as dened by the
manufacturer, to ensure the same eciency and contaminant reduction performance.
Avg. Recovery Rating (%) * : 59.4 %
Avg. Efciency Rating (%) * : N/A
Avg. Daily Water Production (gpd): 359.2 Gallons per day
*Recovery Rating means the percentage of the inuent water to the membrane portion of the system that is available to the user as R/O treated water when the system is operated without a
storage tank or when the storage tank is bypassed.
*Eciency Rating not applicable to tankless RO systems.
Replacement lter and membrane part number: PL400GF-HYBRID; PL400GF-RO