7.5 Fishbox, Cooler and Storage Compartment Drains
The fishbox below the cockpit floor is drained overboard by a macerator pump-out system. The macerator
is activated by a momentary switch located in a switch panel in the cockpit below the gunwale. The fishboxes
should be flushed out and cleaned after each use.
The cooler located under the aft seat drains by gravity to overboard thru-hulls located in the hull sides just
above the waterline.
The macerator discharge pump can only be run dry for a few seconds. Allowing the macerator pump to run
after the fishbox is empty may cause damage to the pump.
7.6 Water System Drains
All exterior sinks and livewells, provided with fresh or raw water, drain by gravity to overboard thru-hulls
located in the hull sides just above the waterline. The overflows in the livewell drain into the overboard drains.
7.7 Cabin Drains
A drain plug in the cabin sole is provided to drain water that may accumulate on the cabin floor. This plug
keeps the aft bilge isolated from the cabin and should be removed only to drain water from the cabin floor
and be reinstalled when the draining is complete.
TO KEEP THE CABIN FREE OF FUMES, VAPORS AND WATER, ALWAYS REPLACE AND
PROPERLY SECURE THE DRAIN PLUG IN THE CABIN SOLE AFTER DRAINING.
7.8 Rope Locker Drains
The rope locker drains overboard through a special drain fitting located in the hull side at the bottom of the
rope locker. It is important to inspect the drain frequently to remove any accumulated debris.
7.9 Drainage System Maintenance
It is essential that the following items be done periodically to maintain proper drainage of your boat:
Clean the cockpit drain rails with a hose to remove debris that can block water drainage.
Clean the hardtop leg drain holes. This is especially important just before winter lay-up.
Clean the bilge pump and automatic float switch strainers of debris and check the bilge for foreign material
that can cause the automatic switch to malfunction.