Owner`s manual
C 230
113
• The strainer on the intake scoop is clogged pre-
venting the water from getting to the pump. Put the
boat in reverse to clean the strainer.
• There is an air lock in the system. Run the boat
above 15 m.p.h. and the pick up scoop will force the
air lock past the pump and prime the system.
• The thru-hull valve is not open. Open valve.
• The valve in the livewell is not open. Open the
valve in the livewell.
• The in-line fuse near the battery switch has blown.
Replace the fuse.
• The pump impeller is jammed by debris. Clean
pump impeller housing.
• The pump is defective. Replace pump.
ACCESSORY PROBLEMS
The livewell pump runs, but does not pump water.
The automatic float switch on the bilge pump raises
but does not activate the pump.
PROBLEM CAUSE AND SOLUTION
TROUBLESHOOTING
GUIDE