Owner`s manual

C 260
38
will light. If this should happen, make sure the main breaker on the panel is in the “OFF” position and turn
the dock power switch or breaker off. A special relay attached to the main breaker should automatically turn
the main breaker off whenever reverse polarity is achieved. Notify a qualified electrician to check the wiring
at the dock outlet. If the red polarity light does not illuminate when power is supplied to the panel, the polarity
is correct and the AC main switch can be moved to the “ON” position.
SWIMMING NEAR A BOAT OPERATING ON AC ELECTRICAL SYSTEM CAN LEAD TO
SEVERE SHOCK AND DEATH. NEVER SWIM OR ALLOW SWIMMING WHEN THE AC
SYSTEM IS IN USE.
DO NOT ATTEMPT TO CORRECT THE WIRING YOURSELF. ELECTRIC SHOCK CAN
CAUSE SEVERE INJURY OR EVEN DEATH. ALWAYS HAVE A QUALIFIED ELECTRICIAN
CHECK WIRING.
KEEP CHILDREN AWAY FROM ANY ELECTRICAL CABLES OR EQUIPMENT AND AL-
WAYS USE GROUNDED APPLIANCES ON BOARD YOUR BOAT.
DO NOT OPERATE THE AC ELECTRICAL SYSTEM FROM SHORE POWER WITH RE-
VERSE POLARITY. REVERSE POLARITY WILL DAMAGE THE SYSTEM AND EXPOSE
PASSENGERS TO ELECTROCUTION HAZARDS. THIS CONDITION COULD ALSO CAUSE
A FIRE IN THE ELECTRICAL SYSTEM.
DISCONNECTING PROCEDURE FOR SHORE POWER CONNECTION
Turn the main breaker on the AC panel to the “OFF” position.
Turn the disconnect switch on the dockside outlet to the “OFF” position.
Disconnect the cable from the dockside outlet and replace the
outlet caps. Disconnect the cable from the boat and replace the
inlet cap. Store cable.
AC BREAKER PANEL
The AC panel is located below the helm in the console storage
compartment. The following are descriptions of the AC panel
equipment and the breakers that protect the accessories:
AC Main Breaker
Protects the general distribution network. This breaker is very
sensitive. The resulting power surge that occurs when connecting
the dockside cord may cause the main breaker to trip. To avoid
this surge, always turn the main breaker to the “OFF”
position before plugging or unplugging the shore power cord.
Polarity Light
The red light indicates reverse polarity current supplied to the panel. This situation will cause the red light
AC Breaker Panel