The generator is located in the aft bilge machinery space. The generator is
equipped with a splash shield that is easily removable for service. As indicated
on the splash shield, this is not to be used as a step. Please refer to the
Ventilation System chapter. The generator compartment is equipped with an
automatic fire extinguisher system and an automatic engine shutdown system.
Refer to the Safety Equipment chapter.
FUEL INJECTED GENERATORS REQUIRE BLEEDING OF AIR FROM THE FUEL DELIV-
ERY SYSTEM PRIOR TO INITIAL START-UP. BLEEDING OF THE FUEL SYSTEM WILL
ALSO BE REQUIRED IF THE GENERATOR IS ALLOWED TO RUN OUT OF FUEL. CON-
TINUED ATTEMPTS TO START THE GENERATOR WITHOUT BLEEDING THE FUEL SYS-
TEM UNDER THESE CIRCUMSTANCES CAN LEAD TO ENGINE DAMAGE OR ERRATIC
OPERATION. THIS PROCEDURE MUST BE COMPLETED BY YOUR SERVICING DEALER.
GENERATOR PANEL
These switches control the starting, running, blower,
AC power selector and stopping of the generator. The
procedures may vary depending on the model and type
of generator installed in your boat. An owner operator's
manual for the generator has been supplied with this
manual. Please refer to it for details on the generator
operation.
Generators charge the battery just enough to compen-
sate for the DC electrical current the engine requires to operate. Therefore, it is important to activate the battery
charger to maintain the house battery whenever the generator is running.
GENERATOR ENGINES PRODUCE CARBON MONOXIDE WHICH IS A LETHAL, TOXIC GAS
THAT IS COLORLESS AND ODORLESS. IT IS A DANGEROUS GAS THAT WILL CAUSE
DEATH IN CERTAIN LEVELS. ONLY OPERATE THE GENERATOR IN WELL VENTILATED
AREAS AND NEVER OPERATE THE GENERATOR WHILE YOU ARE SLEEPING.
AC POWER SELECTOR SWITCH
The generator panel will be equipped with this switch if the optional AC generator has been installed in your
boat. Move the selector switch to the “SHORE” position when connected to dockside power. Move the selector
switch to the “OFF” position when disconnecting the dockside power or when no AC power is being supplied
or for starting the generator. Move the selector switch to the “GENERATOR” position when the generator
is being operated.
DO NOT ATTEMPT TO START THE GENERATOR WITH THE SELECTOR SWITCH IN
THE "GENERATOR" POSITION. WAIT UNTIL THE GENERATOR HAS WARMED UP BE-
FORE TRANSFERRING THE ELECTRICAL LOAD. ONCE THE GENERATOR HAS RUN FOR
THREE OR FOUR MINUTES, PLACE THE SWITCH IN THE "GENERATOR" POSITION.
Generator Panel
NOTICE
Generator Cover