To fill the livewell, insert the plug into the drain fitting at the bottom of the livewell. Make sure the valve
at the intake thru-hull fitting is open and activate the livewell switch. When the water level reaches the
overflow, it will begin to circulate.
To drain the livewell, turn off the livewell pump and pull out the plug in the drain fitting at the bottom of
the livewell. When the livewell has completely drained, use the washdown hose to flush the livewell and drain
debris.
The livewell supply thru-hull valve should be closed whenever the livewell is not in use. This will prevent
water from entering the livewell while the boat is cruising.
DO NOT USE THE LIVEWELL AS A DRY STORAGE AREA WHEN IT IS NOT IN USE.
SEA WATER COULD ACCIDENTALLY BE DELIVERED TO THE LIVEWELL FROM THE
THRU-HULL FITTING AND DAMAGE EQUIPMENT STORED THERE.
DO NOT RUN THE LIVEWELL PUMP DRY FOR EXTENDED PERIODS AS DAMAGE TO
THE PUMP WILL RESULT.
5.5 Drainage
GENERAL
All water is drained by gravity to overboard thru-hull fittings located in the hull sides above the waterline.
Some of the drain thru-hull fittings are equipped with ball valves that are always open under normal operating
conditions. In the event of an emergency, the valves can be closed to prevent sea water from entering the boat
through the drainage system. It is important to check and operate the drain valves at least monthly to make
sure they are in good condition and operating properly. You also should check the drain system frequently
to ensure it is free flowing and that the hoses on the thru-hull fittings are secure and not leaking.
Please review the drainage schematic to become familiar with the location of the thru-hull drain valves.
SITUATIONS REQUIRING ONE OR MORE DRAIN VALVES TO BE CLOSED CAN BE PO-
TENTIALLY DANGEROUS TO THE BOAT AND YOUR CREW. IF THIS OCCURS, DISTRIB-
UTE PERSONAL FLOTATION DEVICES TO THE CREW AND TAKE ALL NECESSARY
SAFETY PRECAUTIONS, INCLUDING NOTIFYING THE COAST GUARD, UNTIL THE PROB-
LEM IS FOUND AND CORRECTED.
COCKPIT DRAINS
Your Pursuit has two drains located in the rear of the cockpit. Water is channeled away from all hatches by
a gutter or drain rail system. The water then drains overboard through the drain system.
HARDTOP DRAINS
There is a hole drilled in one of the leg bases to prevent water from being trapped within the leg and provide
a wire chase for accessories. A small hole is drilled in the tubing at the base of the other legs, which are not
drilled for a wire chase, that allows water to drain.