INSTALLATION INSTRUCTION 2013:6 Purusline Living Wetroom Solution 600 Stainless Steel Grate Planning Information and Installation Instructions Purusline Living Wetroom Solution 600 for 1400x920mm Tray & Twist or Drop Stainless Steel Grate p2-8 for installation into joists Purusline Living Wetroom Solution 600 for 1400x920mm Tray & Twist or Drop Stainless Steel Grate p9-15 for installation into concrete Our ongoing product development may cause changes in the specifications. We reserve these rights.
Purusline Living Wetroom Solution 600 Denna handling får ej utan vårt medgivande kopieras. Den får ej heller delgivas annan eller eljest obehörigen användas. Överträdelse härav beivras med stöd av gällande lag. Purus AB This document must not be copied without our written permission, and the contents thereof must not be imported to a third party nor be used for any unauthorized purpose. Contravention will be prosecuted.
PURUSLINE LIVING WETROOM SOLUTION Important Read all the pages of these instructions fully and thoroughly before you commence installing and keep in a safe location for future reference. Always watch the installation DVD as an aid to installation prior to installing. www.purusgroup.com Plumbing All plumbing work should be carried out by a fully qualified professional plumber. 1½ inch ABS pipe adapter/connector provided.
Wooden floor PURUSLINE LIVING WETROOM SOLUTION 1. Grate x1 3 This document must not be copied without our written permission, and the contents thereof must not be imported to a third party nor be used for any unauthorized purpose. Contravention will be prosecuted. Purus AB PURUS CENTRE LINEAR Wet Room Solution Wooden floor 2.
PURUSLINE LIVING WETROOM SOLUTION Wooden floor If there is any movement or flexing whatsoever on the joists or floorboards, then they need to be made good and solid before installing. To make good, you must add structural supports and/or braces to the joists and/or floorboards. If there is still movement, do not fit the product. Stage 1 Ensure the walls and floor are free from dirt and protruding nails and objects and that the floor coverings have been removed.
PURUSLINE LIVING WETROOM SOLUTION Wooden floor Stage 4 Place the gully and joist installation rails in position and check it is level and 10mm above the floor. Once level, screw and fix into the joists using the screws supplied. If you have 22mm floorboards you will need the packers for 22mm floorboards. Place these on the joists before screwing and fixing the gully and rails into the joists. Do not use power tools. Waste pipes If your waste pipe is an ABS plastic 1½ inch or 42.
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT Wooden floor PURUSLINE LIVING WETROOM SOLUTION Stage 6 Level the floor with 18mm marine plywood (not supplied) or appropriate tile backer boards. Fix the 18mm marine plywood or tile backer boards to the floorboards in accordance to BS5385 for ceramic tiles. Ensuring you avoid screwing through any pipework, cables etc.
PURUSLINE LIVING WETROOM SOLUTION Wooden floor Stage 9 For tiles of height between 10-26mm the six or eight adjustment screws are available in two separate lengths in order to manage tiles between 10-26mm. Adjust the height of the adjustment screws to the height of the tile including the thickness of the bed of tile adhesive you are going to use, so it is flush with the top of the tiles. Never use power tools to screw in the screws.
Purusline Living Wetroom Solution 600 This document must not be copied without our written permission, and the contents thereof must not be imported to a third party nor be used for any unauthorized purpose. Contravention will be prosecuted.
PURUSLINE LIVING WETROOM SOLUTION Important Read all the pages of these instructions fully and thoroughly before you commence installing and keep in a safe location for future reference. Plumbing All plumbing work should be carried out by a fully qualified professional plumber. 1½ inch ABS pipe adapter/connector provided. CHECK LIST/SAFETY NOTES • Ensure you have all the contents supplied before installation. If you do not have all the contents do not install. Contact your distributor straight away.
1 3 1. Grate x1 Wooden floor PURUS CENTRE LINEAR Wet Room Solution P u r u s - UK - Installation instruction Minimax 50 Two Part Tile - 02833 - 20 111220 Purusline Living Linear Wetroom Solution This document must not be copied without our written permission, and the contents thereof must not be imported to a third party nor be used for any unauthorized purpose. Contravention will be prosecuted. Purus AB 2. Grate support for installation x1 (To be removed when installation is complete) 2 4 3.
centralt i förhållande tänkt placering av ra För att få sil/ram symm placerad i duschen mås brunnsdelen monteras duschutrymmets mittli Concrete Concrete Concrete Step 2 PURUSLINE LIVING WETROOM SOLUTION PURUS CENTRE LINEAR 800 Wet Room Solution PURUS CENTRE LINEAR 800 Wet Room Solution Bredd på Linear Wetroom 800 gully is installed on the same level as sealing/tanking Linear Wetroom 800 gully is installed layer. on the same level as sealing/tanking layer.
Concrete PURUSLINE LIVING WETROOM SOLUTION Place the gasket around the gully to check if it fits. Take the Pura Elastomeric Tapes and dry cut to all wall and floor joints. Puragum PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT TCUDORP LANOITACUDE KSEDOTUA NA YB DECUDORP TCUDORP LANOITACUDE KSEDOTUA NA YB DECUDORP TCUDORP LANOITACUDE KSEDOTUA NA YB DECUDORP Once the MS Polymer has tacked over, using a brush or roller apply the Puragum to all wall and floor joints one at a time.
PURUSLINE LIVING WETROOM SOLUTION Concrete Stage 10 After adjusting the height, turn the frame upside-down and fill the frame-edge fully with tile adhesive to fix the grate into position. Then turn the frame back over and install it while the adhesive is still wet. NOTE: When installing, the whole area around the frame should be fully filled with adhesive. Clean any excess tile adhesive that might fall into the gully straight away. Tile adhesive The grate when installed must be horizontal and flat.
NOTES 02835 15
CLEANING AND MAINTENANCE 11 1. Lift out the water trap as above. 2. If necessary, rinse the water trap underwater as shown in picture 2. 3. Replace the water trap. 22 Hold the water trap with the spring loaded body open whilst rinsed clean. Alternatively you may use a brush. Make sure the gaskets are completely clean so the trap is watertight. Ensure when placed back that the gully is fully inserted so the gasket is watertight using two thumbs at each side.