Specifications
PV Powered LLC  15  11-18-28-704 
2.3.d Connecting Through the Optional AC DC Disconnect Box 
 (PVP1100 Model Only) 
Refer to Figure 16 for a diagram of the AC and DC wiring when using the optional PV 
Powered AC DC Disconnect Box.  Ensure all connections are wired correctly and properly 
torqued. The nominal value of tightening torque to be applied to the clamping screws for 
the breakers is 2.0 – 2.5 Nm (18-22 LB-IN). 
 Figure 16: AC and DC wiring with the AC DC Disconnect Box 
 Figure 17: Views of the AC DC Disconnect Box 
Line
Filter
Control pcb
Power Distribution PCB
DC
Power
Supply
L
N
GND
PV GND
+
-
15 A SB
System Block Diagram
120 VAC
 60Hz
90-180 VDC
To dedicated
AC circuit
PV
 DC input
15 A DC Breaker
 &GFI
1A
15A
15A
15 A
AC Breaker
GND
LN
PVP 1100
PV Positive Negative Ground
AC DC
Disconnect