Technical information

96
Hexadecimal
Value
Display String Description
0001 HEATSINK TEMP A1 Module heat-sink A1 temperature high
0002 HEATSINK TEMP A2 Module heat-sink A2 temperature high
0004 HEATSINK TEMP B1 Module heat-sink B1 temperature high
0008 HEATSINK TEMP B2 Module heat-sink B2 temperature high
0010 HEATSINK TEMP C1 Module heat-sink C1 temperature high
0020 HEATSINK TEMP C2 Module heat-sink C2 temperature high
0040 BOARD TEMP HI Control board temperature high
0080 DRIVE TEMP LOW Drive temperature low
0100 MAGNETICS TEMP HI Magnetics temperature high
0200 AMBIENT TEMP LOW Ambient temperature low
0400 MAG TEMP LOW Magnetics temperature low
0800 IPM TEMP HIGH IPM temperature high
Table D-7 Temperature Fault (TMP)
The following table lists the miscellaneous system faults.
Hexadecimal
Value
Display String Description
0001 GROUND FAULT Ground fault
0002 AC CONTACTOR AC contactor fault
0004 DC CONTACTOR DC contactor fault
0008 WD TIMER Watchdog fault
0010 CPU LOAD CPU load fault
0020 RESTART LIMIT Too many fault restarts
0040 CONFIGURATION Conî‚¿guration fault
0080 CURRENT IMBALANCE AC current imbalance
0100 AC VOLTAGE SENSE No AC voltage detected
0400 THERMAL SWITCH OPEN Thermal switch open
0800 DICSONNECT OPEN Disconnect open
Table D-8 System Faults (SYS)