7 Instruction Manual

PVI INDUSTRIES, INC.
FORT WORTH, TEXAS 76111
PV 6347 3/00 (800) 784-8326
QuickDraw
®
BOILER WATER
NICKELSHIELD
®
NICKEL-PLATED
INSTANTANEOUS PACKAGED WATER HEATER
SINGLE-WALL HEAT EXCHANGER
MODEL
NUMBER
GPM RECOVERY
@ 200°F BOILER WATER
BOILER WATER PUMP MOTOR
120V, 1Ø, 60 Hz.
COLD
INLET
HOT
OUTLET
BOILER WATER
CONNECTION NPT
APPROX
SHIP
40 to 120°F 40 to 140°F HP AMPS
NPT NPT
INLET OUTLET
WEIGHT
10 N A-IW 10 6.2 1/3 8 3 2 3 1-1/4 820 #
20 N A-IW 20 12.1 1/3 8 3 2 3 1-1/4 830 #
45 N A-IW 45 27.8 1 16 3 3 4 2-1/2 900 #
Recoveries are based on a 20°F boiler water temperature drop.
For other boiler water temperatures see form PV 6362.
Maximum electrical requirements: 120V, 1Ø, 60 Hz., 24 amps, to single point connection
Intra-tank Circulators:
HP Amps Volts
10 N A-IW 1/7 1.7 120V, 1Ø, 60 Hz.
20 N A-IW Pump Not Required for Temperature Control Accuracy
45 N A-IW 1/3 8 120V, 1Ø, 60 Hz.
Dimensions are in inches unless otherwise noted.
3/4" anchoring
bolt holes