Data Sheet

2
0
Version 1.0
Table 16 – LoRa electrical characteristics
Symbol Description Conditions Min Typ. Max Unit
ACR_LCW
Adjacent channel rejection
FRF = 903 MHz
Interferer is 1.5*BW_L from the
wanted signal centre frequency 1%
PER, Single CW tone = Sensitivity
+ 3dB
SF = 7 60 dB
SF = 12 72 dB
IMR_LCW
Image rejection after
calibration
1% PER, Single CW tone = sensitivity
+ 3dB
66 dB
FERR_L
Maximum tolerated frequency
offset between transmitter
and receiver, no sensitivity
degradation, SF6 thru 12
All BW, +/–25% of BW
The tighter limit applies (see
below)
±25% BW
Maximum tolerated frequency
offset between transmitter
and receiver, no sensitivity
degradation, SF10 thru 12
SF = 12 –50 50 ppm
SF = 11 –100 100 ppm
SF = 10 –200 200 ppm
SF = 10 –200 200 ppm
14.2 Specications